Dimplex S1 7KS 4ACCESSORIES, 5TRANSPORT, Brine Manifold, Brine Pressostat, Accessories Transport

Models: S1 7KS

1 24
Download 24 pages 23.16 Kb
Page 5
Image 5
ACCESSORIES TRANSPORT

ACCESSORIES TRANSPORT

4ACCESSORIES

4.1 Brine Manifold

The brine manifold ties the individual collector loops of the heat source system into a single main line which is connected to the heat pump. Integrated ball valves allow individual brine circuits to be shut off for venting purposes.

4.2 Brine Pressostat

Where this is a legal requirement, a low-pressure brine pressostat may be installed in the unit. In this case, the connection provided above the brine expansion vessel should be used.

5TRANSPORT

A lift truck is suited for transporting the unit on a level surface. If the heat pump needs to be transported on an uneven surface or carried up or down stairs, carrying straps may be used for this type of transport. These straps may be passed directly underneath the wooden pallet.

CAUTION! The heat pump is not secured to the wooden pallet.

CAUTION! The heat pump must not be tilted more than max. 45° (in either direction).

For lifting the unit without pallet, the holes provided in the sides of the frame should be used. The side panel assemblies must be removed for this purpose. A commercially available pipe can be used as a carrying aid.

CAUTION! Do not use the holes in the panel assemblies for lifting the unit!

5

Page 5
Image 5
Dimplex S1 7KS operating instructions 4ACCESSORIES, 5TRANSPORT, Brine Manifold, Brine Pressostat, Accessories Transport