Dimplex WB7, WB15, WB3, WB5E 1 SERVICE WARNING LIGHT All Models except WB5E, Constant, 8 or

Models: WB7 WB5E 1 WB3 WB15

1 13
Download 13 pages 13.75 Kb
Page 12
Image 12

SERVICE WARNING LIGHT (All Models except WB5E)

All models except WB5E have this facility. This light is designed to help you discover the cause of any malfunction. If the circuit senses a problem, the service light will flash a number of times and then pause and repeat this sequence. Count the number of flashes between pauses and refer to the table on the back cover. Some serious service problems will disable the boiler whist less serious ones will allow you to continue to operate until a convenient time arises for the fault to be rectified.

NUMBER OF

 

MEANING

ACTION

FLASHES

 

 

 

BETWEEN

 

 

 

PAUSES

 

 

 

1 Constant

Water level sensor has scaled up

Clean Sensing Probes

 

at normal level and machine has

 

 

filled to a higher level

 

2

Operating level sensor has been

Clean Sensing Probes

 

detected but lower level sensor

 

 

has not

 

3

Overfill level sensor has been

Clean Sensing Probes

 

detected but other sensors have

 

 

not

 

4

Danger level sensor has been

Clean Sensing Probes

 

detected and machine functions

 

 

have been shut down

 

5

Thermistor or potentiometer have

Call service department on

 

failed

01704 502911

 

 

 

Quoting the Serial Number

6

Boiler has failed to fill in the

Check water supply

 

allotted time. Possible causes :-

 

 

1.

Water supply turned off.

If in order call Instanta

 

2.

Water inlet valve has failed.

service department quoting

 

3.

Blockage in water inlet pipe.

the Serial Number

 

4. Pipe connecting inlet valve to

 

 

 

boiler has become detached.

 

 

5. Bottom sensor is scaled up

 

7

The temperature sensor

Call service department on

 

(thermistor) has become

01704 502911

 

disconnected or the heating

Quoting the Serial Number

 

element(s) have failed.

 

8 or 9

Fault on temperature sensor

Call service department on

 

(thermistor).

01704 502911

 

 

 

Quoting the Serial Number

10

Heating element(s) faulty .

Call service department on

 

 

 

01704 502911

 

 

 

Quoting the Serial Number

11

The water supply has been

Check water supply

 

interrupted and the level has

 

 

 

 

 

12

Page 12
Image 12
Dimplex WB7, WB15, WB3, WB5E 1 instruction manual SERVICE WARNING LIGHT All Models except WB5E, Constant, 8 or