Dimplex WB15, WB7, WB3, WB5E 1 instruction manual Rear Entry, Overflow Pipe Bottom Entry

Models: WB7 WB5E 1 WB3 WB15

1 13
Download 13 pages 13.75 Kb
Page 5
Image 5

BOTTOM ENTRY

Connect to a suitable cold drinking water supply using 15mm copper pipe and push on the ‘T’ piece supplied. The ‘T’ has been blanked off using a brass plug. Leave this plug in place. Push the ‘T’ piece firmly onto the water inlet solenoid pipe with the brass plug facing forward. Then push the 15mm cold water supply firmly into the bottom of the fitting.

To avoid damage to the unit, do not use any solder connections whilst pipes are connected to the boiler.

REAR ENTRY

For rear entry of cold water supply, remove the plug from the ‘T’ piece by compressing the grey collar and pulling out. Push the plug firmly into the bottom of the ‘T’ piece.

Push the ‘T’ piece firmly into the water inlet solenoid pipe with the ‘T’ facing the wall.

Push the 15mm cold water supply firmly into the ‘T’ fitting.

To avoid damage to the unit, do not use any solder connections whilst pipes are connected to the boiler.

OVERFLOW PIPE BOTTOM ENTRY

In your fitting kit you will find a straight push on connector with a small length of 15mm copper tube pushed into it.

This connector must be pushed onto the corresponding overflow pipe on the bracket (alongside the solenoid).

If you wish to extend the overflow, remove the copper pipe supplied and replace with pipe of your chosen length. The pipe must have a continuous fall and should not be longer than 200mm (if a longer run is required use 22mm pipe to avoid airlocks). The overflow pipe should have no more than four right angle bends and should discharge to a safe visible position.

Under certain conditions, the overflow pipe could vent steam, hot water or cold water and the manufacturers cannot be held responsible should damage arise from such discharge if the overflow pipe has not been directed to a suitable position where overflowing water can run away safely.

Under no circumstances should the overflow pipe be allowed to vent inside the case of the boiler.

5