installation guide
ProSecurity
Model SR6000
Page
table of contents
warning! safety first
before beginning the installation
installation points to remember
after the installation
locations for the control module
locations for the siren
deciding on component locations
locations for stinger doubleguard shock sensor
locations for valet/program switch
locations for the status LED
finding the wires you need
locations for the optional starter kill relay
locations for the relay satellite
obtaining constant
finding the 12V switched ignition wire
finding the starter wire
finding the tachometer wire
finding the accessory wire
finding the wait-to-startbulb wire for diesels
finding a + parking light wire
finding the door pin switch circuit
making your wiring connections
auxiliary harness H2, 6-pinconnector
primary harness H1, 12-pinconnector
H1/1
H1/2
door lock harness, 3-pinconnector
remote start ribbon harness, wiring diagram
heavy gauge relay satellite wiring diagram
remote start harness H3, 5-pinconnector
H3/1
H3/2
primary harness H1 wire connection guide
H1/3 WHITE/BLUE remote start -activation input
H1/5 GREEN -door trigger input, zone
H1/11 RED +12V constant power input
H1/8 BLACK -chassis ground connection
H1/10 BROWN + siren output
H1/12 RED/WHITE channel 2, 200mA -output
secondary harness H2 wire connection guide
Chevrolet and GMC trucks - Light blue or dark blue
Relay for Negative -Disarm Wire
ORANGE + accessory output
PINK/WHITE + second ignition accessory output
PINK + ignition output
RED/WHITE + 12V input
H3/2 GRAY -hood pinswitch input, zone
H3/3 BROWN + brake switch input, zone
H3/1 BLUE/WHITE -status output
H3/4 VIOLET/WHITE tachometer input
neutral safety switch interface
testing the neutral safety switch
sense wire shutting down the unit prematurely
2005 Directed Electronics, Inc. Vista, CA
bypassing GM vehicle anti-theftsystems VATS
passlock I and passlock II PL-1and PL-2
passkey III PK-3, transponder-basedsystems
programmer interface, 3-pinblack plug
plug-inLED and valet/program switch
GREEN -multiplex input, zone
shock sensor harness, 4-pinconnector
BLUE -multiplex input, zone
tach learning
programming jumpers
To learn the tach signal
4. Release the Valet/Program switch
light flash +
tach threshold on/off
transmitter/receiver learn routine
FUNCTION
transmitter configurations
standard configuration
multi-levelsecurity arming
system features learn routine
The learn routine will be exited if
feature menus
menu #1 - basic features
menu #2 - advanced features
menu #3 - remote start options
feature descriptions
menu #1 - basic features
menu #2 - advanced features
1-9AUTOMATIC ENGINE DISABLE AED ON/OFF AED is a full-time,passive starter disable that works independ- ently of the security system. When turned on, the orange, ground-when-armedoutput H1/1 will activate 30 seconds after the ignition is turned off. The LED will flash at half its normal rate when the ignition is turned off to indicate that AED is active and will interrupt the starter in 30 seconds. AED does not occur in Valet mode and can be bypassed using the emergency override procedure. The transmitter can be used to disarm AED, however, the system must be armed and then disarmed, using the transmitter, to disarm AED
Page
menu #3 - remote start options
tion from 1-60minutes
Page
nuisance prevention circuitry
valet mode
timer mode
table of zones
to perform shutdown diagnostics
shutdown diagnostics
long term event history
safety check
troubleshooting
alarm troubleshooting
remote start troubleshooting
2.Check diagnostics
wiring quick reference guide
relay satellite wiring
quick reference guide
Ungo Pro Security 661 W. Redondo Beach Blvd
Get Started Get Protected
Gardena, Ca. 800-GO-CLARION