CARE AND MAINTENANCE

HYDROSTATIC TRANSMISSION OIL & FILTER SERVICE:

If transmission is to be serviced, proper air purging procedures must be followed, or damage will occur.

1.Remove oil filter from chassis allowing oil to drain into container. Clean impurities from inside of reservoir,

if necessary.

2.Fill new filter with oil (not doing so can cause air pocket in system and possible hydro damage). Install new oil filter to chassis. Use only genuine Dixon replacement oil filter. (Using any other brand of oil filter may not be internally compatible and could cause damage to hydrostat transmission.)

3.Put fresh oil in reservoir. Fill reservoir to full mark.

4.Remove two oil return hoses from top of oil reservoir and direct these hoses into a container for oil draining.

40

Page 40
Image 40
Dixon 13089-0601 manual Hydrostatic Transmission OIL & Filter Service