Dixon 18134-1004 manual Testing Of Safety Interlock Systems, Operation Instructions

Models: 18134-1004

1 52
Download 52 pages 24.27 Kb
Page 24
Image 24
TESTING OF SAFETY INTERLOCK SYSTEMS:

OPERATION INSTRUCTIONS

TESTING OF SAFETY INTERLOCK SYSTEMS:

Manual background Failure to observe the following testing instructions could result in serious injury or death.

The following tests should be performed at the start

of each mowing day.

PARKING BRAKE SWITCH TEST:

a)Swing control levers to outward position

b)Disengage blade drive switch

c)Put parking brake in OFF position

d)Turn ignition switch to START

Engine should not turn over or attempt to start.

CONTROL LEVER SWITCH TEST:

a)Disengage blade drive switch

b)Put parking brake in ON position

c)Swing control levers inward

d)Turn ignition switch to START

Engine should not turn over or attempt to start.

NOTE: If any safety check fails, do not operate the

mower until the system has been checked and repaired by an Authorized Dixon® Dealer.

24

Page 24
Image 24
Dixon 18134-1004 manual Testing Of Safety Interlock Systems, Operation Instructions