2.3.2Audio Connections

Dolby Installation Guidelines

Unit Connections and Dimensions

 

 

 

 

2.3.2Audio Connections

The digital audio inputs and reference input are provided on female BNC connectors. Input signals should be compliant with AES3-id-1995 (unbalanced, 75Ω , 1V peak-to- peak standard output). AES3-id signals are very similar to analog composite video, although dedicated AES3 distribution equipment should be used. If the loop-through BNC connectors are not being used to feed additional equipment, terminate them with a standard 75Ω video terminator.

The digital audio output is provided on a female BNC connector. The output is 75Ω, unbalanced, with signal levels compliant with AES3-id-1995.

2.3.3Serial I/O (Remote)

The DP563 allows remote control via the front-panel (RS-232) or rear-panel (RS-

485) ports. It is able to communicate at rates of 9.6 kbps, 19.2 kbps, or 38.4 kbps. The unit address can be any discrete tributary address as specified in SMPTE RP 113- 1996. See Section 6.4 for further information. The default address is 8280, and the serial I/O connections can also be used for software upgrades.

2.3.4Auxiliary Data

The Aux Data port is an RS-485 port that may be used for future enhancements. See Section 5.2 for pin assignments.

2.4 DP569

Figure 2-4Front and Back Panels of DP569

2.4.1Dimensions

The DP569 occupies one rack unit and measures 44 ⋅ 483 ⋅ 324 mm (1.75 ⋅ 19 ⋅ 12.75 inches). Its net weight is 4.7 kg (10.3 lb).