Chapter 6

Dolby Installation Guidelines

Chapter 6

Serial Communications

These products all feature RS-485 and/or RS-232 connections. These can be used to upgrade the unit software or to control the operation of the unit. The electrical and mechanical specifications for these ports are as SMPTE 207M. The pin assignments for these connections are shown in the tables below. For information about the remote protocol, contact Dolby Laboratories.

6.1RS-232 Ports

DP562 Serial I/O (female)

DP572 Auxiliary Data (male)

Table 6-1Pin Connections for 9-Pin RS-232 Ports (DP562 and DP572)

Pin

Connection

Comment

1

DCD

Direct connection to DTR, DSR, and CTS

2

RX

Asynchronous data out

3

TX

Asynchronous data in

4

DTR

Direct connection to DCD, DSR, and CTS

5

GND

Signal ground

6

DSR

Direct connection to DCD, DTR, and CTS

7

NC

 

8

CTS

Direct connection to DCD, DTR, and DSR

9

NC

 

 

 

 