You have purchased a marine air conditioner that will add to your boating enjoyment. Please read the accompanying instructions to insure proper installation, operation and care.
Warnings
The use of the
The National Electrical Code recommends the use of a cord labeled with LCDI or AFCI when connecting a room air conditioner to power. LCDI stands for Leakage Current Detection and Interruption; AFCI stands for Arc Fault Circuit Interruption. Both help prevent fires and electrical shock. Dometic recommends that you contact your dealer and request part LCDI25 (25' cord) or purchase a similar cord from another supplier.
The
Dimensions & Hatch Size
The
(838mm) Long and 16" (406mm) Wide. For proper installa- tion, the minimum hatch size is 12" (305mm) square, and the maximum hatch size is 24" (610mm) square. The minimum round hatch diameter is 15 1/2" (394mm).
Important Information
Please make sure you have the following items. If you are missing any of these items please contact your dealer.
(1)
(1)Hatch Bag
(1)Air Deflector
(2)23" Batten Rods
(2)
Before installing the unit you will need:
A power extension cord rated at 15 amps for 115V unit or 10 amps for a 220V unit. (See section, “Safe Operation of
Optional 3/8" I.D. (Inside Diameter) Flexible drain tubing (See section, “Installation Instructions”)
Power Requirements
For 115 Volt Units (50/60Hz Operation)
115/60/1 dockside power Running amps: 6.9 A Starting amps: 21 A Minimum Voltage: 104 VAC Minimum Circuit: 15 A
For 220 Volt Units (50Hz Operation Only)
220/50/1 dockside power Running Amps: 3.4 A Starting Amps: 10 A Minimum Voltage: 198 VAC Minimum Circuit: 10 A
Inverter/Generator Operation
In order to use the
Safe Operation of Carry-On
1.Use cord labled with LCDI or AFCI to connect to power source (see warning).
2.Using the
3.Prevent accidents or damage to
4.Do not disassemble
5.Be certain the
6.Physical and electrical conditions vary greatly from location to location.
(a.) Be sure the electrical service is adequate and equipped with a circuit breaker (15 amps minimum for 115V units, 10 amps minimum for 220V units).
(b.) Use a
4 | ❖ English |