(c.) DANGER - SHOCK HAZARD! Do not, under any circumstances, cut or remove the grounding prong from the end of your power cord. Your Carry-On must be used with a three-prong grounding power cord and connected to a properly grounded and polarized three prong receptacle. DO NOT USE AN ADAPTOR PLUG, OR A TWO BLADE ADAPTOR PLUG THAT BYPASSES THE GROUNDING IN ANY WAY!!!

(d.) It is always desirable to have your on-board or shoreside receptacle protected by a time delay fuse or circuit breaker.

7.If the Carry-On operation is interrupted (turned off, plug pulled out, thunderstorm, etc., accidentally or otherwise)

Wiring Diagram

after operation in the COOL mode, WAIT 3 MINUTES BEFORE RESTARTING. This allows pressure inside the compressor to equalize. Consequences of attempted restart within the 3 minute period may be a tripped circuit breaker or blown fuse. In this case, turn Carry-On to “OFF”, reset breaker (or replace fuse), wait 3 minutes, then restart.

8.If the Carry-On has been stored in any position other than upright within 10 degrees of level, then, after installing, wait

30minutes to allow compressor oil to settle to the bottom of the compressor. Otherwise permanent damage may occur, voiding the warranty.