Dometic DM2862 installation procedure, Electrical connection, maximum total Conductor wire length

Models: DM2862

1 40
Download 40 pages 40.62 Kb
Page 10
Image 10
RM2351, RM2451, RM2551, DM2652 & DM2852

installation procedure

9.Put back the cover.

10.Press the ON/OFF button off and then back on. Nor- mal operation of the burner should return.

11.Allow the burner to operate for a minimum of five minutes.

RM2351, RM2451, RM2551, DM2652 & DM2852

To test the gas safety shut off, follow these steps:

1.Start the refrigerator without connecting to

120V AC.

2.Check that the gas flame is lit. In AUTO mode, the AUTO mode indicator lamp is on.

3.Follow steps 3-11 in the previous instruction.

Electrical connection

120 V AC connection

The refrigerator is equipped with a grounded three-prong plug for protection against shock hazards. It should be plugged di- rectly into a properly grounded three-prong receptacle. Do not cut or remove the grounding prong from this plug!

The free length of the cord is 2 feet. It should be routed to avoid direct contact with the burner cover, flue cover or any other components that could damage the cord insulation.

To allow easy access through the vent door, it is recommended that the receptacle is placed like this:

12V DC connection

RM2451, RM2551, DM2652 & DM2852: These refrigerator models are not designed for 12V DC operation of the cooling system. However, 12V DC must be supplied to operate the controls.

RM2354, RM2454, RM2554, DM2662, DM2663, DM2862, DM3862 & NDM1062: These refrigerator models require a continuous 12V DC supply to maintain the automatic energy system.

The connection is made to the positive (+) and negative (-) terminals of the terminal block on back of the refrigerator.

Correct polarity must be observed when connecting to the DC supply. Do not use the chassis or vehicle frame as one of the conductors. Connect two wires at the refrigerator and route to the DC supply. Ensure the connections are clean, tight and free from corrosion.

Ensure that the wires from the battery to the refrigerator are able to handle the load. The distance the current must travel from the battery to the refrigerator dictates the AWG wire size to be used. Inadequate wire sizes can result in a voltage drop which affects the refrigerator performance.

For 3-way models, the voltage drop affects the wattage output of the 12V cartridge heater and the refrigerator performance. The 12V DC heater is fused with a 30 amp. in-line blade fuse.

Recommended wire sizes are displayed in the following table:

RM2351 & RM2354

To the left of the refrigerator and 4-6”above the refrigerator

maximum total Conductor wire length

mounting floor

 

WIRE

Size

 

Length
RM2451, RM2454, RM2551, RM2554, DM2652 &

 

MODEL

 

 

 

DM2852

 

AWG

ft

m

To the left of the refrigerator and 6” above the refrigerator

RM2351

14

17

5

mounting floor

 

 

RM2451

12

27

8

DM2662, DM2663, DM2862, DM3862 & NDM1062

RM2551

To the left of the refrigerator and 3” above the refrigerator

DM2652

 

 

 

mounting floor.

 

DM2662

 

 

 

NDR1292

 

DM2852

 

 

 

To the right of the refrigerator and 10” above the refrigerator

DM2862

 

 

 

mounting floor.

 

DM3862

 

 

 

 

 

NDM1062

 

 

 

 

 

NDR1292

 

 

 

RM2451, RM2454, RM2551,

NDR1292

RM2354

10

17

5

RM2554, DM2652, DM2662,

RM2454

8

27

8

 

DM2663, DM2852, DM2862,

 

RM2554

 

 

 

 

DM3862 & NDM1062

 

DM2663

 

 

 

120V AC

120V AC

 

 

 

 

receptacle

receptacle

 

 

 

 

olt AC

 

 

 

 

 

tacle

 

 

 

 

 

3”

10”

 

 

 

 

4-6”

 

 

 

 

 

 

 

 

 

6”

 

 

 

 

 

 

- 10 -

 

 

 

Page 10
Image 10
Dometic DM2862 installation procedure, Electrical connection, RM2351, RM2451, RM2551, DM2652 & DM2852, Length, Wire, Model