Startup

6! warning

FIRE HAZARD. Before lighting the gas burner, after that the RV has not been used for some time, please check that the gas path between the burner jet and the burner tube has not been obstructed. Failure to heed this warning could cause a fire resulting in personal injury.

SOLENOID VALVE

BURNER MOUNTING

SCREWS

Startup INLET FITTING

BURNER JET

MANUAL SHUT OFF VALVE

BURNER TUBE .

(Shown in open position)

PRESSURE TEST PORT

SPARK ELECTRODE

Before starting the refrigerator:

Check that all the manual gas valves are in the ON position.

Make sure that a continuous 12V DC supply is available for the electronic control to function.

To start the refrigerator:

•AUTO - AES/AUTO mode 1. Press the ON/OFF button.

2.Select operation mode:

AUTO - AES/AUTO mode

AC and GAS.

Press the AUTO/GAS - AES/AUTO/GAS mode selector button (if not already on). The illuminated lamp indicates the selected mode.

(If the CHECK indicator lamp is illuminated, see

refrigerator overview > Modes of operation > AUTO mode - AES/AUTO mode for further information.)

GAS mode

GAS operation only.

Press the AUTO/GAS - AES/AUTO/GAS mode selector button to turn off the AUTO mode (if not already off).

(Within 45 seconds the burner should be ignited and operating normally. If not, see Refrigerator overview > modes of operation > gas mode for further information.)

DC mode (3-way models only)

Press the DC mode indicator button. The DC lamp will be turned on. To select AUTO or GAS mode, turn off the DC mode by pressing the DC mode se- lector button. The DC lamp will then be turned off.

3.If necessary, adjust the thermostat by pressing the Temperature selector button.

(RM2351, RM2451, RM2551, DM2652 & DM2852: The temperature is controlled by a factory preset temperature setting.)

Turning on the climate control

DM2652, dm2662, dm2663, dm2852, dm2862, NDM1062 & NDR1292

Turn the Climate control switch to I (ON).

The Climate control switch is located beneath the top decoration panel that houses the control panel.

DM3862, NDM1062 & NDR1292

Press the CLC button. The indicator lamp will illuminate.

ON

 

AES

COLD 1 2 3 4 5 COLDEST

CLC

LAC

 

AUTO

OFF

AC

GAS

CHECK

 

 

Turning on the low ambient control

NDM1062 & NDR1292

Turn the Low ambient control switch to I (ON).

The Low ambient control switch is located beneath the top decoration panel that houses the control panel.

DM3862, NDM1062 & NDR1292

Press the LAC button. The indicator lamp will illuminate.

ON

 

AES

COLD 1 2 3 4 5 COLDEST

CLC

LAC

 

AUTO

OFF

AC

GAS

CHECK

 

 

turning off the refrigerator

The refrigerator may be shut off while in any mode of opera- tion by pressing the main power ON/OFF button to the OFF position. This shuts off all DC power to the refrigerator, includ- ing the interior light.

If the refrigerator will not be in operation for a period of weeks, it should be emptied, defrosted, cleaned and the doors left ajar. The ice trays should also be dried and kept outside the cabinet.