Installation Instructions
Certification and Code Requirements
This appliance is certified under the latest edition of ANSI Z21.19•CSA 1.4 Refrigerators using gas fuel. The installation must conform with local codes, or in absence of local codes, the following standards as applicable.
In the U.S. the installation must conform with:
•National Fuel Gas Code, ANSI Z223.1/NFPA 54
(latest edition).
•Recreational Vehicles Code, ANSI A119.2 (latest edition).
•Manufactured Home Construction and Safety Standard, Title 24 CFR, Part 3280.
If an external electrical source is utilized, the refrigerator, when installed, must be electrically grounded in accordance with local codes or, in the absence of local codes, the National Elec- trical Code, ANSI/NFPA 70 - (latest edition).
In CANADA, the installation must conform with:
•Natural Gas and Propane Installation Code, CSA B149.1
•CSA Z240 RV Series, Recreational Vehicles.
•Current CSA Z240.4,
If an external electrical source is utilized, the refrigerator, when installed, must be electrically grounded in accordance with local codes or, in the absence of local codes, the Canadian Electrical Code, CSA C22.1, Parts I and II - (latest edition).
Ventilation requirements
General information
Ventilation is one of the requirements for proper cooling unit operation. The installation should be made in such a manner as to separate the combustion system from the living space of the mobile home or recreational vehicle. Openings for air supply or for venting of combustion products should have a minimum dimension of not less than 1/4 inch.
Proper installation requires one lower fresh air intake and one upper exhaust vent. Certified installations require one roof vent and one lower side vent. The ventilation kits shown in this manual have been certified for use with the different models as displayed in the “Certified Vent System Kits” table.
The ventilation kits must be installed and used without modification! An opening toward the outside at floor level in the refrigerator compartment has to be provided for ventilation of
CAUTION
It is of especially importance that the airflow around the burner housing, the boiler insula- tion and the flow of combustion gases must not be obstructed. Items placed in the vicinity of the refrigerator compartment accordingly must be secured away from the refrigerator tubing and flue.
The lower side vent is fitted with a panel, which provides an adequate access opening for ready serviceability of the burner and control manifold of the refrigerator. This should be centered on the back of the refrigerator.
Certified Vent System Kits
Model | Kit | Components | Part no. |
No. | |||
RM2351 | 2A | Roof Base | 3103633.XXX* or 3310893.XXX* |
RM2354 |
| Roof Cover | 3103634.XXX* or 3310894.XXX* |
|
| Lower Side Vent | 3109350.XXX* |
|
| Lower Side Vent | RM183 |
| 3A | Upper Side Vent | RM123A |
|
| Lower Side Vent | RM183 |
|
| Power Vent Ass’y | 3108705.751** |
|
| Upper Side Vent | RM123A |
|
| Upper Side Vent | 3109492.003 |
|
| Lower Side Vent | RM183 |
|
| Lower Side Vent | 3109492.003 |
RM2451 | 3A | Roof Base | 3103633.XXX* or 3310893.XXX* |
RM2454 |
| Roof Cover | 3103634.XXX* or 3310894.XXX* |
RM2551 |
| Lower Side Vent | 3109350.XXX* |
RM2554 |
|
|
|
DM2652 | 4A | Roof Base | 3103633.XXX* or 3310893.XXX* |
DM2662 |
| Roof Cover | 3103634.XXX* or 3310894.XXX* |
DM2663 |
| Lower Side Vent | 3109350.XXX* |
DM2852 |
|
|
|
DM2862 |
|
|
|
DM3862 |
|
|
|
NDM1062 |
|
|
|
ndr1292 | 5A | Roof Base | 3103633.XXX* or 3310893.XXX* |
|
| Roof Cover | 3103634.XXX* or 3310894.XXX* |
|
| Lower Side Vent | 3103649.XXX* |
|
| Power Vent Ass’y | 3108705.744** |
*Replace “XXX” with the color code numbers. For color codes, contact your supplier.
**Alternate instructions forwarded with the Ventilator Kit.
For further information, contact your dealer or distributor.
- 4 -