F.FUSES

FIG. 16

10)Reinstall burner, being careful that the end of the burner fits into the slot on the burner bracket. Check to make sure slots are centered under the flue tube and the thermocouple is positioned prop- erly (tip of thermocouple extends over two slots of burner).

11)Be sure to reconnect the wire to high voltage electrode. Check the electrode for proper location and gap. (See FIG. 17).

FIG. 17

ELECTRODE

 

1/8" TO 3/16"

 

(3-5 mm)

 

 

BURNER TUB

12)Turn on manual gas shutoff valve and check all fittings for leaks.

13)Connect 120 volt power cord to the outlet and reconnect or turn on the 12 volt DC power.

14)Check LP gas safety shutoff. See Section A. Instal- lation, Item 9. Testing LP Gas Safety Shutoff.

F.FUSES

The refrigerator is equipped with two fuses; one for the refrigerator control system, and one for the AC cartridge heat. (See Table below) To replace fuse(s), proceed as follows:

1.Disconnect the wall plug and the 12 volt wires.

2.Remove the power module cover. See FIG. 12.

3.Snap the fuse out of the fuse holder.

4.Fit a new fuse into the fuse holder.

5.Replace the power module cover.

Control System

3-amp

 

 

AC Heater

5-amp

 

 

(3. Troubleshooting

Continued on Page 14)