Dometic Elite RM7732 manual Ventilation Heights, Clearances, Lower Vent Cutout

Models: Elite RM7732

1 14
Download 14 pages 59.97 Kb
Page 3
Image 3
5. VENTILATION HEIGHTS

5. VENTILATION HEIGHTS

Refer to FIG 1., Page 2

Installation with roof

Minimum Ventilation

vent and lower side vent

heights in:

 

 

 

 

REFRIGERATOR

INCHES

MM

 

 

 

RM7732

65

1651

 

 

 

 

LOWER VENT CUTOUT

 

 

3-1/2"

 

13-3/4"

 

 

 

 

 

 

 

3-1/2"

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

28-7/8"

NOTE: RADIUS CAN BE +1/4"–0"

HEIGHT AND WIDTH ± 1/8"

6. CLEARANCES

Minimum clearances in inches to combustible materials are:

G:

Top

0"

K:

Side

0"

L:

Bottom

0"

M:

Rear

0"

N:

 

65"

NOTE: Clearance "M" is between the rearmost part of the refrigerator and the wall behind the refrigerator.

NOTE: Clearance "N" is the distance between the bottom of the lower vent to the roof material. For ventilation height, refer to Section A. Installation, Item 5. Ventilation Heights. See FIG. 2.

 

NOTE: Wood strip MUST be in

FIG. 2

place. See Page 4, Item 7

 

 

 

 

 

 

 

 

FIG. 3

Refrigerator

 

Overall

 

 

Recess

 

Model

 

Dimensions

 

 

Dimensions

 

 

 

 

 

 

 

 

 

 

RM7732

Height

Width

Depth

Height

Width

 

Depth

 

 

A

B

C

H

W

 

D

 

 

 

 

 

 

 

 

 

 

(Inches)

59-5/8

33-9/16

25-15/16

59-1/16

32-11/16

 

24

 

 

 

 

 

 

 

 

 

(mm)

1523

852

659

1498

830

 

610

 

 

 

 

 

 

 

 

 

3

Page 3
Image 3
Dometic Elite RM7732 Ventilation Heights, Clearances, Lower Vent Cutout, NOTE RADIUS CAN BE +1/4-0 HEIGHT AND WIDTH ± 1/8