Dometic RM2812, RM2612 manual Ventilation Heights, Clearances, Lower Vent Cutout, Upper Vent Cutout

Models: RM2812 RM2612

1 12
Download 12 pages 60.63 Kb
Page 3
Image 3
5. VENTILATION HEIGHTS

5. VENTILATION HEIGHTS

Refer to FIG 1., Page 2

Installation with roof

Minimum

Ventilation

vent and lower side vent

heights in:

 

 

 

 

REFRIGERATOR

INCHES

 

MM

 

 

 

 

RM2612

54

 

1372

RM2812

60

 

1524

 

 

 

 

LOWER VENT CUTOUT

13-3/4"

21-9/16"

UPPER VENT CUTOUT

5-1/2"

23-3/4"

NOTE: All cutout dimensions are +/– 1/8".

6. CLEARANCES

Minimum clearances in inches to combustible materials are:

G:

Top

0"

K:

Side

0"

L:

Bottom

0"

M:

Rear

0"

N:

 

See NOTE

NOTE: Clearance "M" is between the rearmost part of the refrigerator and the wall behind the refrigerator.

NOTE: Clearance "N" is the distance between the bottom of the lower vent to the roof material. For ventilation height, refer to Section A. Installation, Item 5. Ventilation Heights. See FIG. 2.

FIG. 2

FIG. 3

Refrigerator

 

Overall

 

 

Installation

 

 

Recess

 

 

Model

 

Dimensions

 

 

Dimensions

 

 

Dimensions

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Height

Width

Depth

Height

Width

Depth

Height

Width

Depth

 

 

A

B

C

h

w

d

H

W

D

 

 

 

 

 

 

 

 

 

 

 

 

RM2612 (Inches)

51

22-23/32

24-9/16

49-7/32

21-17/32

23-19/32

49-17/32

21-13/16

24-3/32

 

 

 

 

 

 

 

 

 

 

 

 

 

 

(mm)

1295

577

624

1250

547

599

1258

544

612

 

 

 

 

 

 

 

 

 

 

 

 

 

RM2812 (Inches)

56-13/16

24-39/64

24-9/16

55-1/8

23-7/16

23-19/32

55-7/16

23-11/16

24-3/32

 

 

 

 

 

 

 

 

 

 

 

 

 

 

(mm)

1443

625

624

1400

595

599

1408

601

612

 

 

 

 

 

 

 

 

 

 

 

 

 

3

Page 3