DreamGEAR N313, P186, P314, N185 Locating Heater, Unconfined Space, Confined Space

Models: N313 N185 P186 P314

1 23
Download 23 pages 21.4 Kb
Page 6
Image 6
Unconfined Space

Unconfined Space

An unconfined space whose volume is not less than 50 cubic feet per 1,000 BTU/HR of the aggregate input rating of all appliances installed in that space. Rooms communicating directly with the space in which the appliances are installed, through openings not furnished with doors are considered a part of the unconfined space.

Confined Space

A confined space whose volume is less than 50 cubic feet for each 1,000 BTU/HR of the aggregate input rating of all appliances in that space.

WARNING : You must provide additional ventilation air in a confined space.

For proper operation of the unit, provide fresh air opening(s) to the room. Follow the National Fuel Code NFPA 54 / ANSI Z223.1, for required size of combustion and ventilation openings.

NOTICE : A qualified service person must install heater. Follow all local codes.

CHECK GAS TYPE : Verify the type of gas supply to be used, either natural or LP(Propane), and make sure the marking on the appliance rating plate agrees with that of the supply gas. The rating plate is located on the side of the heater, which indicates the type of gas that heater is orificed for.

ITEMS NEEDED FOR HEATER INSTALLATION: Before installing heater, make sure you have the items listed below:

Gas Piping (check local codes.). Test gauge connection Sealant (resistant to LP gases) Manual shutoff valve* Sediment trap

Ground joint union

Tee joint and pipe wrench

An installer supplied, design-certified manual shutoff valve with 1/8" NPT tap connection.

LP gases installation, also requires an installer supplied, design certified gas pressure regulator.

LOCATING HEATER:

This heater is designed to be mounted on a wall. Heater can be located on floor, away from a wall. An optional floor mounting base is needed, purchase the floor mounting base from your dealer.

Confined SpaceLOCATING HEATER: WARNING : Never install the heater

in a bedroom or a bathroom in a recreational vehicle

where curtains, furniture, clothing, or other flammable objects are less than 36 inches from the front, top, or sides of the heater

as a fireplace insert

Page 5

Page 6
Image 6
DreamGEAR N313, P186, P314, N185 installation manual Locating Heater, Unconfined Space, Confined Space