Dri-Eaz 1400 Operating Instructions, Front and Right Side View, Back and Left Side View

Models: 1400

1 12
Download 12 pages 18.34 Kb
Page 2
Image 2

PARTS IDENTIFICATION (Shown, below)

Touchpad temperature controls

OPERATING INSTRUCTIONS

GETTING STARTED

PLACEMENT:

Left side

Duct D (Cold outlet)

Duct B (Heat outlet)

For cooling or heating, place at least one EB1400 per room.

1.

Place the unit on a level surface.

2.

Make sure the System switch is set to Off then plug power

 

cord into a standard 115v grounded outlet.

3.

Set the digital temperature controls needed to function

 

(see below).

Condenser

Front filter (Inlet)

Drain Hose

pocketBack housing (filter set located inside)

Right side

Wheel casters

Rotomolded

 

shell

Front and Right Side View

Touchpad temperature controls

Duct A (Heat inlet back

of unit)Rotomolded shell

Cord pocket

Left side

Wheel casters

Back and Left Side View

4. Check for proper operation before leaving the unit

unattended. Do not move or carry the EB1400 when it is

running or plugged in.

OPERATING RANGE

Recommended operating range is between 60° – 115° F. The EB 1400 will not function properly when operating in environment with temperatures outside this range.

CYCLE TIMES AND COMPRESSOR PROTECTION

The EB1400 thermostat includes an automatic compressor protection feature to avoid potential damage to the cooling system from short cycling. This thermostat automatically provides a 5-minute delay after turning off the cooling system output to protect the compressor. This protection is also present while operating the unit in heating applications.

Important Notes:

If unit loses power or gets unplugged during operation, operator MUST wait 5 minutes before plugging unit back in or risk damaging the compressor or tripping the circuit breaker in the facility.

Always turn the System switch to OFF before unplugging.

If the System setting is adjusted during operation the unit will automatically delay 5 minutes before start-up.

When switching unit from cooling to heating or heating to cooling operator must adjust setpoint temperature.

TESTING AND PROGRAMMING THERMOSTAT

DIGITAL CONTROLS

Digital screen

Reset

Up

Down

 

 

Fan

On

Cool

Off

Heat

Auto

07-01583B 06-07 Copyright 2007 Dri-Eaz Products, Inc.

2

Page 2
Image 2
Dri-Eaz 1400 owner manual Operating Instructions, Front and Right Side View, Back and Left Side View, Important Notes