WARNING : DO NOT USE OPEN FLAME TO CHECK LEAKS.

13.Install a 1/8” NPT plugged tapping for test gauge connection immediately upstream of the gas supply connection to the appliance.

14.Install a shutoff valve to the gas line. Tighten securely using a pipe joint compound.

15.Install a 3/8” flex connector to connect the shutoff valve to the gas valve on the fireplace. Tighten securely using a pipe joint compound.

16.Check the gas line piping for leaks. Use a soap and water solution.

WARNING : DO NOT USE OPEN FLAME TO CHECK LEAKS.

17.If you decided to make a direct connection to the fan step 8, remove the power cord and connect the 120 V line. To do so, unscrew the speed control unit and pull away from the junction box a few inches. Unscrew the two mar connectors attached to the cord (P) and the cord ground. Remove the cord and route the supply line through the same holes. Make the electrical connection with the same wires the cord was attached to. Screw the ground wire to the junction box (G).

If you prefer to use the six foot cord supplied, just connect it to a 120 V outlet.

18.If you want to turn the main burner ON and OFF using a wall switch :

8

Page 9
Image 9
Drolet 36C03U TYPE 139, 7000 MVRLC manual Warning Do Not Use Open Flame To Check Leaks