![TROUBLESHOOTING GUIDE](/images/new-backgrounds/175010/17501023x1.webp)
TROUBLESHOOTING GUIDE
PROBLEMS | CAUSES |
|
| SOLUTION |
| ||
ON POSITION 6 (MAXIMUM) | Position 6 was reached too | 1. | Set | flow | regulating handle | ||
THE FLAME IS LONG AND | quickly. |
| to position 1. |
|
| ||
SMOKY, THERE IS SUIT |
| 2. | wait | for | combustion | to | |
BUILD UPON THE GLASS |
|
| stabilize. |
|
|
| |
|
| 3. | Progressively increase flow | ||||
|
|
| to desired position. |
| |||
|
| NOTE : | SEE | LIGHTING | |||
|
| PROCEDURES. |
|
| |||
| Maximum flow is too high | 1. | Set flow to a lower position | ||||
|
| 2. | Call | a qualified | technician | ||
|
|
| to adjust the valve. |
| |||
ON POSITION 1 (MINIMUM) | Cleaning tee and/or burner are | 1. | Activate | cleaning | tee | ||
THE FLAME PRODUCES | dirty |
| according to procedures |
| |||
SMOKE AND SUITS THE |
| 2. | Schedule at the next shut | ||||
GLASS |
|
| off to clean the burner. |
| |||
| Orifice of plunger is partially | 1. | Progressively increase flow | ||||
| plugged. |
| to position 6. |
|
| ||
|
| 2. | Push | in | manual | ||
|
|
| consecutive times on | the | |||
|
|
| thermostatique | regulator | |||
|
|
| bottom to remove dirt form | ||||
|
|
| the orifice. |
|
|
NOTE : If the problem persist, you may have to remove and clean out the valve with alcohol.
Call your specialized technician.
ON POSITION 1 (MINIMUM) | Flow is to low | 1. | Slightly | increase the flow | |
THE FLAME PRODUCES |
|
| regulating handle. | ||
SMOKE AND SUITS THE |
| 2. | Call | a | specialized |
GLASS |
|
| technician. |
|
Page 11 of 15