Drolet ALASKA 2000 manual Troubleshooting Guide, Problems, Causes, Solution

Models: ALASKA 2000

1 16
Download 16 pages 33.97 Kb
Page 12
Image 12
TROUBLESHOOTING GUIDE

TROUBLESHOOTING GUIDE

PROBLEMS

CAUSES

 

 

SOLUTION

 

ON POSITION 6 (MAXIMUM)

Position 6 was reached too

1.

Set

flow

regulating handle

THE FLAME IS LONG AND

quickly.

 

to position 1.

 

 

SMOKY, THERE IS SUIT

 

2.

wait

for

combustion

to

BUILD UPON THE GLASS

 

 

stabilize.

 

 

 

 

 

3.

Progressively increase flow

 

 

 

to desired position.

 

 

 

NOTE :

SEE

LIGHTING

 

 

PROCEDURES.

 

 

 

Maximum flow is too high

1.

Set flow to a lower position

 

 

2.

Call

a qualified

technician

 

 

 

to adjust the valve.

 

ON POSITION 1 (MINIMUM)

Cleaning tee and/or burner are

1.

Activate

cleaning

tee

THE FLAME PRODUCES

dirty

 

according to procedures

 

SMOKE AND SUITS THE

 

2.

Schedule at the next shut

GLASS

 

 

off to clean the burner.

 

 

Orifice of plunger is partially

1.

Progressively increase flow

 

plugged.

 

to position 6.

 

 

 

 

2.

Push

in

manual

 

 

 

consecutive times on

the

 

 

 

thermostatique

regulator

 

 

 

bottom to remove dirt form

 

 

 

the orifice.

 

 

NOTE : If the problem persist, you may have to remove and clean out the valve with alcohol.

Call your specialized technician.

ON POSITION 1 (MINIMUM)

Flow is to low

1.

Slightly

increase the flow

THE FLAME PRODUCES

 

 

regulating handle.

SMOKE AND SUITS THE

 

2.

Call

a

specialized

GLASS

 

 

technician.

 

Page 11 of 15