![CONNECTING THE STOVE TO THE CHIMNEY](/images/new-backgrounds/175010/1750109x1.webp)
CONNECTING THE STOVE TO THE CHIMNEY
•The gases are vented from he back of the unit. The female part of the black pipe connector has to be installed toward the flue connector of the stove. Secure all connections with the (3) self taping screws, with 120o distance between each of them.
•The connection between stove pipes and chimney has to be perfectly sealed.
•A maximum horizontal lent of 5' is allowed. Make sure to have a 1/4" slope per foot minimum.
•Do not use more than two 90o Elbows while connecting the stove to the chimney.
•It is strictly forbidden to pass through combustible materials walls, floors and ceilings with stove pipe connectors. Ref : Standard
• DIRECT HORIZONTAL CONNECTION : | • CEILING CONNECTION : |
You may choose to connect your stove to | In the case where your chimney starts from |
the chimney with an horizontal flue pipe. | the ceiling, use one 90º elbow and the |
| necessary straight sections. |
Figure 6: | HORIZONTAL CONNECTION . | Figure 7: | CEILING CONNECTION . | ||||
• | DO NOT CONNECT MORE THAN ONE | • VERTICAL CONNECTION : | |||||
IT is recommended to not use more than two | |||||||
| STOVE TO YOUR CHIMNEY. |
| |||||
|
| (2) 90º elbows and the necessary straight | |||||
• FIX | FLUE PIPES TOGETHER | WITH | sections | to connect your stove to the | |||
| METAL SCREWS. |
|
| chimney. |
| ||
• MAKE SURE YOU RESPECT A ¼’’ SLOPE |
|
| |||||
| PER FOOT OF HORIZONTAL PIPE |
|
| ||||
| LENGTH. |
|
|
|
| ||
• RESPECT CAREFULLY CLEARANCES TO |
|
| |||||
| COMBUSTIBLES PRESCRIBED BY FLUE |
|
| ||||
| PIPES MANUFACTURERS. |
|
|
| |||
• | FLUE | PIPES | CLEARANCES | TO |
|
| |
| COMBUSTIBLES | DEPEND ON | FLUE |
|
| ||
| PIPES TYPE AND MANUFACTURERS | Figure 8: | VERTICAL CONNECTION . | ||||
|
|
|
|
|
Page 4 of 15