CEILING SUPPORT SYSTEM

7- Authorities require that the chimney extend not less than 3 feet above the highest point where it passes through the roof of a building and not less than 2 feet above any portion of the building within 10 feet. If the chimney extends more than 5 feet above the roof deck, roof guys with telescoping legs and draw bands are required.

8- Finally, twist on your rain cap and you can head back inside.

9- You are now ready to connect your chimney to your stove. Simply install the inter-connecting stove pipe between the stove pipe adapter and the stove. You can follow the instructions in the following sections of this manual under « COUPLINGS ».

CEILING SUPPORT SYSTEM

If your chimney must rise inside the house and go through the ceiling, you need to connect it to your stove at the ceiling level. For this type of installation, the following items are normally required :

Chimney

An adequate number of chimney sections (enough to go up to your roof)

A ceiling support kit with stove pipe adapter

An attic insulation shield

A roof flashing kit

A chimney cap

Roof guys (if necessary)