POSITIONING THE STOVE

It is very important to position the wood stove as close as possible to the chimney, and in an area that will favor the most efficient heat distribution possible throughout the house. The stove must therefore be installed in the room where the most time is spent, and in the most spacious room possible. Recall that wood stoves produce radiating heat, the heat we feel when we are close to a wood stove. A wood stove also functions by convection, that is through the displacement of hot air accelerated upwards and its replacement with cooler air. If necessary, the hot air distribution from the stove may be facilitated by a blower or the installation of floor or wall grids. Except for model FX3000, it is strictly forbidden to install your wood stove in a mobile home.

Important:

A wood stove must never be installed in a hallway or near a staircase, since it may block the way in case of fire or fail to respect required clearance. The wood stove must not be hooked up to a hot air distribution system since an excessive accumulation of heat may occur.

FLOOR PROTECTION

Your woodstove should be placed on a non-combustible surface. Having these minimum specifications.

FLOOR PROTECTION

 

Models

 

Thickness of

 

Front Protrusion

 

Side Protrusions

 

Rear Protrusion

 

 

 

Sheet

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Baron 1880sp

 

1/4" (6mm)

 

18" (457mm)

 

8" (203mm)

 

10" (152mm)

 

 

 

 

 

 

 

 

 

 

 

 

 

Baron 2000sp

 

1/4" (6mm)

 

18" (457mm)

 

8" (203mm)

 

10" (152mm)

 

 

 

 

 

 

 

 

 

 

 

 

 

Cassandra

 

1/4" (6mm)

 

18" (457mm)

 

6" (152mm)

 

6" (152mm)

 

 

 

 

 

 

 

 

 

 

 

 

 

Classic

 

1/4" (6mm)

 

18" (457mm)

 

8" (203mm)

 

8" (203mm)

 

 

Compak

 

1/4" (6mm)

 

18" (457mm)

 

8" (203mm)

 

8" (203mm)

 

 

Contempro 1300

 

1/4" (6mm)

 

18" (457mm)

 

8" (203mm)

 

8" (203mm)

 

 

 

 

 

 

 

 

 

 

 

 

 

Contempro 1600

 

1/4" (6mm)

 

18" (457mm)

 

8" (203mm)

 

8" (203mm)

 

 

 

 

 

 

 

 

 

 

 

 

 

Contempro 2000

 

1/4" (6mm)

 

18" (457mm)

 

8" (203mm)

 

8" (203mm)

 

 

 

 

 

 

 

 

 

 

 

 

 

CS1200

 

1/4" (6mm)

 

18" (457mm)

 

8" (203mm)

 

8" (203mm)

 

 

FX 3000

 

1/4" (6mm)

 

18" (457mm)

 

8" (203mm)

 

N/A

 

 

Gemini 1200

 

1/4" (6mm)

 

18" (457mm)

 

6" (152mm)

 

6" (152mm)

 

 

 

 

 

 

 

 

 

 

 

 

 

Gemini 1500

 

1/4" (6mm)

 

18" (457mm)

 

6" (152mm)

 

6" (152mm)

 

 

 

 

 

 

 

 

 

 

 

 

 

Jasper

 

1/4" (6mm)

 

18" (457mm)

 

6" (152mm)

 

6" (152mm)

 

 

 

 

 

 

 

 

 

 

 

 

 

Klondike

 

1/4" (6mm)

 

18" (457mm)

 

6" (152mm)

 

6" (152mm)

 

 

Little Sawman

 

1/4" (6mm)

 

18" (457mm)

 

8" (203mm)

 

8" (203mm)

 

 

Lorraine

 

1/4" (6mm)

 

18" (457mm)

 

6" (152mm)

 

6" (152mm)

 

 

 

 

 

 

 

 

 

 

 

 

 

ML

 

1/4" (6mm)

 

18" (457mm)

 

6" (152mm)

 

6" (152mm)

 

 

 

 

 

 

 

 

 

 

 

 

 

Patriarch

 

1/4" (6mm)

 

18" (457mm)

 

8" (203mm)

 

8" (203mm)

 

 

 

 

 

 

 

 

 

 

 

 

 

RC

 

1/4" (6mm)

 

18" (457mm)

 

8" (203mm)

 

8" (203mm)

 

 

Nordic

 

1/4" (6mm)

 

18" (457mm)

 

8" (203mm)

 

8" (203mm)

 

 

Royal Comfort

 

1/4" (6mm)

 

18" (457mm)

 

10" (254mm)

 

10" (254mm)

 

 

 

 

 

 

 

 

 

 

 

 

 

Sawman

 

1/4" (6mm)

 

18" (457mm)

 

10" (254mm)

 

10" (254mm)

 

 

 

 

 

 

 

 

 

 

 

 

 

Sawyer

 

1/4" (6mm)

 

18" (457mm)

 

8" (203mm)

 

10" (254mm)

 

 

 

 

 

 

 

 

 

 

 

 

 

Settler

 

1/4" (6mm)

 

18" (457mm)

 

10" (254mm)

 

10" (254mm)

 

 

Whistler , DLX

 

1/4" (6mm)

 

18" (457mm)

 

6" (152mm)

 

6" (152mm)

 

6