Drolet SIT 0.820.634 Nova manual Maintenance Instructions, Shutdown procedures, Glass maintenance

Models: SIT 0.820.634 Nova

1 15
Download 15 pages 5.71 Kb
Page 11
Image 11
Shutdown procedures

EXCEL-FIRE GAS STOVE

10

1.Open the pedestal front panel to reach the control.

2.Make sure the gas control knob is turned to the ‘’OFF’’ position. If it is not, press knob slightly and turn clockwise 3 to the "OFF’’ position. Do not force the gas control knob. If the gas control was in the on position you should wait 5 minutes before trying to re-light the stove.

3.If you smell gas STOP and follow instructions on the COVER page.

4.Push in and turn gas control knob counterclockwise 4 to the "pilot" position.

5.Press gas control knob in and hold. Immediately push the red igniter button repeatedly until pilot flame ignites. Continue holding in the control knob for 5 to 10 seconds, and then release it. If the pilot flame goes out, repeat this step.

Note: you might have to push the igniter few times before the pilot flame gets on

6.Push and turn gas control knob counterclockwise 4 to the "on" position.

CAUTION: This stove is hot while in operation. Do not touch. Keep children, clothing and flammable materials away.

Shutdown procedures

Push in and rotate the gas control knob clockwise to the "off" position. Do not force.

If you are going to perform any maintenance or cleaning, first allow the stove to cool completely. Follow the instructions in the section on cleaning under MAINTENANCE INSTRUCTIONS.

MAINTENANCE INSTRUCTIONS

TURN OFF THE GAS WITH THE SHUTDOWN VALVE AND DISCONNECT THE ELECTRICAL POWER BEFORE SERVICING THE APPLIANCE.

The venting system and the gas stove should be inspected at least once a year. Remove the glass front and the logs and clean them if necessary.

The control compartment, air circulating passages, firebox, logs and burner should be cleaned at least once a year by vacuuming or brushing.

Check the pilot flame to see if it is adjusted properly. Readjust the pilot flame if necessary or clean the pilot orifice if readjustment is not possible.

Check the burner for flame lifting or for unusual flame pattern. If necessary clean the burner orifice. For more information, see “Adjustments” in the INSTALLATION section.

Keep the area clear and free from combustible materials, gasoline and other flammable vapours and liquids.

Glass maintenance

We have supplied your EXCEL-FIRE with special ceramic glass which will withstand the heat from the unit without cracking. Be careful not to hit the glass.

NOTE:

Never clean this glass with abrasive cleaners.

Use only a cleaner recommended by your dealer.

Never clean glass while it is still hot. It could stain permanently.

Do not operate the stove with the glass broken or removed