13 |
Pilot assembly
Adjusting air shutter (Venturi)
The factory setting for the air shutter is 1/4” for natural gas, fuily open for propane. After operating the appliance for half an hour or so the flames should have turned a nice yellow colour. However, in higher altitudes you may find a smudging up of the glass after a few days. The shutter should then be adjusted open in 1/16” increments until the glass stays clear. If the flame does not turn yellow the air shutter should be closed until the flame just turns yellow. To access the shutter you need to remove the glass front, the logs and grate. Lift out the hearth surrounding the burner and the shutter will be exposed underneath. Loosen the retaining screw 1 turn before attempting to move the shutter.
OPTIONS
ITEM DESCRIPTION | Part no | |
• | Wall thermostat kit | AC05558 |
• | 130 CFM blower kit with variable speed control | AC05914 |
REPLACEMENT PARTS
ITEM DESCRIPTION | Part no | |
• 6’’ stove pipe adapter | SE9348 | |
• Set of logs 5 | AC05791 | |
• Burner (natural gas or propane) | ||
• Pyroceram Glass (19.446" x 11.737") | ||
• 1/2″ dia. gasket for door | 40020 | |
• U gasket for glass | 40005 | |
• | Blower 130 cfm | 44070 |
• | Variable speed control | 44080 |
• | 44044 | |
• Gas valve (natural gas) SIT | 49133 | |
• Gas valve (propane) SIT | 49126 | |
• Pilot assembly (natural gas) SIT | 49103 | |
• Pilot assembly (propane) SIT | 49106 | |
• | Piezo igniter | 49128 |
• Burner orifice (natural gas #36) | 9071 | |
• Burner orifice (propane #52) | ||
• | Thermocouple | 49122 |
• | Spill switch | 44047 |
• | Thermopile | 49095 |