Drolet SIT 0.820.634 Nova manual Options, Replacement Parts

Models: SIT 0.820.634 Nova

1 15
Download 15 pages 5.71 Kb
Page 14
Image 14
Pilot assembly

EXCEL-FIRE GAS STOVE

13

Pilot assembly

Adjusting air shutter (Venturi)

The factory setting for the air shutter is 1/4” for natural gas, fuily open for propane. After operating the appliance for half an hour or so the flames should have turned a nice yellow colour. However, in higher altitudes you may find a smudging up of the glass after a few days. The shutter should then be adjusted open in 1/16” increments until the glass stays clear. If the flame does not turn yellow the air shutter should be closed until the flame just turns yellow. To access the shutter you need to remove the glass front, the logs and grate. Lift out the hearth surrounding the burner and the shutter will be exposed underneath. Loosen the retaining screw 1 turn before attempting to move the shutter.

OPTIONS

ITEM DESCRIPTION

Part no

Wall thermostat kit

AC05558

130 CFM blower kit with variable speed control

AC05914

REPLACEMENT PARTS

ITEM DESCRIPTION

Part no

6’’ stove pipe adapter

SE9348

Set of logs 5

AC05791

Burner (natural gas or propane)

SE09311-01

Pyroceram Glass (19.446" x 11.737")

SE09335-05

1/2dia. gasket for door

40020

U gasket for glass

40005

Blower 130 cfm

44070

Variable speed control

44080

Thermo-switch (for blower)

44044

Gas valve (natural gas) SIT

49133

Gas valve (propane) SIT

49126

Pilot assembly (natural gas) SIT

49103

Pilot assembly (propane) SIT

49106

Piezo igniter

49128

Burner orifice (natural gas #36)

9071

Burner orifice (propane #52)

9071-01

Thermocouple

49122

Spill switch

44047

Thermopile

49095