7 |
1.Remove the two door retaining screws at the bottom right and left of the door.
2.Remove the door.
3.Locate the log grate in the retainers in the right and left rear corners.
4.Place the rear log (1) against the rear log stop. Make sure grooves at the back of the log line up with the grates log stop.
5.Place logs 2 and 3 against the stops in the middle of the grate. Again see that grooves in the the logs line up with the grates log stop.
6.Place log 4 into the grooves of logs 1 and 2.
7.Log 5 sits over log 4 and 3.
Rock wool fiber installation
One small plastic bag is supplied with your unit its filled with rock wool fiber which, when glowing red, resembles hot embers.
•Place rock wool fiber on top of the front gas ports and up to the grates middle section.
•Put the door back in place. Install the two door retaing screws.
Optional 6-inch pipe installation
Instead of using a standard
Warning: always use an approved gas pipe. Never use a conventional
•Install the first
•Fasten the optional
•Install the sections of the conventional
OPERATION INSTRUCTIONS
Wall thermostat
The optional wall thermostat will automatically keep your room at an even temperature. You need to choose a convenient location for the thermostat. Remember that it should be at least 10 feet from the stove and away from direct radiation of the fire. Run the correct gauge wire (see table) from the valve to the thermostat and wire as shown in the diagram.(on next page)
To operate your
During the heating season, you do not have to touch the gas control valve. If you would like the stove off for a while, just set the thermostat to its minimum setting. However if you do not need the stove for quite some time, follow the procedure outlined in the SHUTDOWN section. This will extinguish the pilot light as well.