Optional blower

EXCEL-FIRE GAS STOVE

8

DISTANCE

DIAMETRE

20 pi

18GA

30 pi

16GA

40 pi

14 GA

50pi

12GA

REMOVE THE BLUE JUMPER BETWEEN TP & TPTH SCREWS ON THE GAS VALVE.

Optional blower

The blower control contains a variable speed switch and a thermal switch. When the stove is operating, the thermal switch will turn on at 110° F, allowing the blower to operate. When the stove cools to 90° F, the thermal switch turns off the blower in about 40 minutes. This prevents the blower from operating when the stove is not in use.

The blower not only helps circulate air throughout the room, it also increases the heat output and efficiency of the EXCEL-FIRE.

Blower electrical connection

Install the blower to the back of the stove using the 4 mounting screws. Than connect the two wires to the motors connectors.

If you wish to make a direct electrical connection to the blower without using the six-foot cord supplied, route a 120 volt, 60 Hz electrical power supply line to the same location. Remove the power cord and connect the 120V line as per the following procedure:

Unscrew the speed control unit and pull a few inches away from the junction box

Unscrew the two marr connectors attached to the cord (P) and the cord ground

Remove the cord and route the supply line through the same holes

Make the electrical connection with the same wires the cord was attached to

Screw the ground wire to the junction box (G)

Screw the speed control unit back in place

CONNECT THE POWER LINE TO THE SAME

P

WIRES THE CORD WAS CONNECTED TO (P)

G

P

Blower electrical connection JUNCTION BOX

Manual background SPEED CONTROL

NOTE: If you prefer to use the six-foot cord supplied by Drolet, just connect it to a 120V outlet.