6TCPUKVKQP&GVGEVQT
674010 67401((
Transition Detector
on/off menu
64#05+6+10&'6'%61410
6JGRTQLGEVQTJCUDGGPVTCPUHGTTGF
HTQORTGXKQWUN[KPUVCNNGFRQUKVKQP

2+0$1:

+H[QWYKUJVQJCXGCUSWCTGKOCIG
QPUETGGPCICKP
FKUCDNG6TCPUKVKQP&GVGEVQTQP/GPW
Transition Detector Alarm

OPTION Menu

OPTION Menu (continued)

Item

Description

SECURITY

4. Using the Transition Detector Function

While the Transition Detector function is ON, when power switch is started to supply to the projector, it might react as below.

Transition Detector alarm shown below might appear on screen, if the projector has been moved or re-installed.

Transition Detector alarm might appear on screen, if the MIRROR setting has been changed.

Keystone adjustment feature has been prohibited as long as the Transition Detector function is ON.

4.1 Turning On the Transition Detector Function

4.1-1 Use the ▲/▼ buttons on the SECURITY menu to select Transition Detector and press the ► or the ENTER button to display the Transition Detector on/off menu. Select TURN ON and the current angle and mirror setting will be recorded.

NOTE: This feature may not function properly if the projector is not in a stable position when TURN ON is selected.

4.1-2 If this function is set to TURN ON when the vertical angle of the projector or mirror setting at which the projector is turned on is different than the previously recorded the Transition Detector Alarm will be displayed and the projector will not display the input signal.

Set the Transition Detector off in the SECURITY menu or set the projector at the recorded angle to display the input signal.

If the Transition Detector ALARM is displayed for about 5 minutes the lamp will turn off. This function will activate only when the projector is started after the power switch was turned off.

4.2 Setting the Transition Detector PASSWORD

4.2-1 Use the ▲/▼ buttons on the SECURITY menu to select Transition Detector and press the ► or the ENTER button to display the Transition Detector on/off menu.

4.2-2 Use the ▲/▼ buttons on the Transition Detector

 

 

6TCPUKVKQP&GVGEVQT

on/off menu to select TURN ON. The ENTER

'06'42#55914&

 

PASSWORD BOX (small) will be displayed.

 



 

4.2-3 Use the ▲/▼/◄/► buttons to enter a PASSWORD.

 

 

 

 

 

37+6

0':6

 

ENTER PASSWORD

Move the cursor to the right side of the ENTER

PASSWORD BOX (small) and press the ► button

 

 

BOX (small)

 

 

6TCPUKVKQP&GVGEVQT

to display the CHECK PASSWORD BOX, enter the

 

 

%*'%-2#55914&

 

same PASSWORD again.

 

 



 

4.2-4 Move the cursor to the right side of the CHECK

 

 

 

 

 

 

 

37+6

0':6

 

PASSWORD BOX and press the ► button to

CHECK PASSWORD

display the PASSWORD for about 20 seconds,

 

 

BOX

 

 

please make note of the PASSWORD during

 

 

6TCPUKVKQP&GVGEVQT

this time. After the PASSWORD has displayed

%1/2.'6'

 

 

 

 

 

 

for about 20 seconds the screen will return to

 



 

the Transition Detector on/off menu.

 

 

 

 

'06'4

':+6

 

Pressing the ENTER button on the remote controll or the

 

 

PASSWORD BOX

INPUT button on the projector will close the PASSWORD BOX. NOTE : Please do not forget your Transition Detector PASSWORD.

48

Page 50
Image 50
Dukane 8776-RJ, 8755E-RJ user manual Using the Transition Detector Function, Turning On the Transition Detector Function

8755E-RJ, 8776-RJ specifications

The Dukane 8776-RJ and 8755E-RJ are advanced ultrasonic welders designed for various industrial applications, particularly in the plastics and textiles sectors. Both machines are part of Dukane's extensive portfolio of ultrasonic technology solutions, renowned for their reliability, precision, and efficiency.

The Dukane 8776-RJ model is engineered for high-speed welding applications. It features a robust design that allows it to operate effectively in demanding environments. One of the hallmark features of this machine is its ability to achieve strong, consistent welds without the need for additional adhesives or fasteners. This capability is crucial for manufacturers looking to streamline production processes while maintaining product integrity.

On the other hand, the Dukane 8755E-RJ offers unique benefits tailored for more specialized applications. It is equipped with a digital processor that enables enhanced control over the welding parameters, allowing users to fine-tune settings such as amplitude, time, and pressure. This not only maximizes the quality of the welds produced but also minimizes material waste, a critical factor in today’s cost-sensitive markets.

Both models utilize advanced ultrasonic technology that converts electrical energy into high-frequency mechanical vibrations. These vibrations are transmitted through a sonotrode and into the parts being joined, creating localized melting at the interface. This process is not only efficient but also ensures that welds are completed in a fraction of the time compared to traditional methods.

The 8776-RJ and 8755E-RJ boast user-friendly interfaces that facilitate easy operation and monitoring. The machines come equipped with touch-screen controls, allowing operators to customize and save settings for repeatability across production runs. This feature is particularly advantageous in high-volume manufacturing environments, where consistency is paramount.

Safety is a crucial consideration in the design of both models. They are built with multiple safety features to ensure operator protection while maintaining functionality. This focus on safety helps to mitigate risks associated with machine operation and enhances overall workplace safety.

In summary, the Dukane 8776-RJ and 8755E-RJ ultrasonic welders represent cutting-edge solutions for industrial welding needs. Their combination of reliability, advanced technology, user-friendly interfaces, and safety features make them ideal choices for manufacturers aiming for high quality and efficiency in their production processes. Whether it’s for high-speed applications or more controlled processes, these machines deliver exceptional performance that meets the demands of modern manufacturing.