Troubleshooting Reference Chart
PROBLEM/ | PROBABLE | LOCATION |
| REASON - CORRECTION |
SYMPTOM | CAUSE |
|
|
|
|
| Ionizing Section of Cell | 1. | Dirty insulator(s) – Clean |
|
|
| 2. | Defective insulator(s) – Replace |
|
|
| 3. | Foreign Object Between Ionizing Bar and Ground |
|
|
|
| electrode - Remove |
|
| Collecting Section of Cell | 1. | Dirty insulator(s) - Clean |
| Short Circuit |
| 2. | Defective insulator(s) – Replace |
|
| 3. | Foreign Material Bridging Plates - Remove | |
|
|
| 4. | Bent Plates – Straighten or Replace |
|
| High Voltage Leads | 1. | Disconnected High Voltage Lead Contacting Ground |
Indicating Light |
|
|
| - Reconnect |
|
| 2. | Defective Lead/Insulation Breakdown – Replace | |
Not Glowing |
|
| ||
|
|
| Entire Lead | |
|
|
|
| |
|
| Power Supply |
| Charred/Over Heated Components – Replace |
|
|
|
| Power Supply |
|
|
|
|
|
|
| Control | 1. | Disconnected Supply Line Power – Reconnect |
|
|
| 2. | Faulty indicting Light - Replace |
|
| Power Supply | 1. | Blown |
Indicating Light | Open Circuit |
| 2. | Disconnected Wire – Replace |
| 3. | Charred/Over Heated Components – Replace | ||
Not Glowing |
|
|
| Power Supply |
|
| Electronic Air Cleaner | 1. | Electrical Interlock Switch Not Closed – Close |
|
| Housing |
| Access Door |
|
|
| 2. | Junction Box interlock switch not closed – Secure |
|
|
|
| Cover |
|
|
| 3. | Faulty Electrical Interlock Switch - Replace |
|
|
| 1. | Ionizer High Voltage Lead Connected to Plate |
|
|
|
| Section and Plate Lead to Ionizer – Reconnect |
|
|
|
| Leads |
Indicating Light | High Resistance | High Voltage Circuit | 2. | Loose or Disconnect high Voltage |
| Reconnect | |||
Flickering | Short |
| 3. | Loose or Defective Intercell Connection (on Multicell |
|
|
|
| Units) – Tighten or Replace |
|
|
| 4. | Foreign Object Adrift in Ionizer or Plate Section of |
|
|
|
| Cell – Remove |
|
|
| 5. | Dirty Cells – Remove, clean and replace. |
|
|
|
|
|