installation error or missing ground. Problems may be caused through missing ground, especially in boats and motor homes with fiber glass body. For these cases, Albrecht offers a special connecting cable with matching box as “artificial ground” (AKM 27)

Some antennas, like “Gamma II” are broadbanded and do not need any retuning during installations.

Even if your AE 5090 has a particularly robust transmitter high- level stage which can even withstand mismatching of SWR=3, you should still never transmit without an antenna!

Operation

Before switching on

Turn SQUELCH and ASC control left (counterclockwise) as far as possible

Switching on and adjusting volume

The on/off switch is combined in the VOLUME control. To switch on:

Turn VOLUME control (the inner knob) from OFF position slightly clockwise.

LC display and buttons are illuminated. Then turn further until desired volume is reached.

Selecting the operating channel

On the radio set:

With the rotary channel knob You can continuously select channels. The present channel is displayed.

On the microphone:

Press the or button on the microphone briefly, to switch up or down a channel.

Press the respective button longer to run up or down through the channels. The present channel is displayed.

Field intensity meter (S-meter)

On the bar graph display You can see approximately how strong the receiving signal is.

The scale under the bar display (S1 to +30) helps with orientation for an input signal in the stages S1 to S9+30dB.

Please note: the field intensity meter only registers a signal when the muting control has opened.

RF Gain setting

You can adjust the overall-sensitivity of Your receiver with the RF gain knob, which is combined with the volume knob (outer ring). Normally, RF gain should be in the full clockwise position. Sometime You may desire to listen only to nearby stations. Or You may receive much interference signals. In such cases You can reduce the sensitivity of Your receiver by turning the knob more counter clockwise.