Dynacord DPA 4410 dimensions Incorporation Into 19 Flightcases or 19 Rack Systems, Fuses

Models: DPA 4410

1 15
Download 15 pages 63.39 Kb
Page 12
Image 12

T101

T104

INPUT 1

INPUT 4

T102

T103

INPUT 2

INPUT 3

TO AMP_A

TO REMOTE CONTROL

TO AMP_B

PCB 84167

PCB 81330.2

PCB 84167

Diagram 9 Printed circuit board 81330.1 with inserted input transformers NRS90208

10.INCORPORATION INTO 19" FLIGHTCASES OR 19" RACK SYSTEMS

Note Do not operate the DPA 4410 without its enclosure or without parts of the enclosure.

When incorporating the DPA 4410 into a 19" flightcase or 19" rack system make sure, that there is sufficient air-flow. Between the amplifier’s rear plate and the back-wall of the surrounding enclosure there has to be at least a space of 60 mm x 330 mm up to the enclosures ventilation gaps. Above the rack system should be at least a space of 100 mm for a sufficient circulation of the air. During the operation of the DPA 4410 the environmental temperature within the rack closet may increase by about 10° C. This has to be taken into consideration when installing other equipment into the same rack system or other enclosures.

Note For trouble-free operation of the appliance, the maximum environmental temperature should not exceed +40° C.

11. FUSES

location

pos.

used for

value

dimensions

standard

 

 

 

 

 

 

fuse switch (11)

F501

mains fuse 230V~ AC

T4A 250V

5 x 20 mm

IEC 127

fuse switch (11)

F501

mains fuse 115V~ AC

T8A 250V

5 x 20 mm

IEC 127

PCB 85264.2

F502

battery fuse 24V DC

25A 32V

flat-type fuse

DIN 72581-3

PCB 85264.2

F503

battery fuse 24V DC

25A 32V

flat-type fuse

DIN 72581-3

PCB 85264.2

F504

power-AMP 1

T6.3A 250V

5 x 20 mm

IEC 127

PCB 85264.2

F505

power-AMP 2

T6.3A 250V

5 x 20 mm

IEC 127

PCB 85264.2

F506

power-AMP 3

T6.3A 250V

5 x 20 mm

IEC 127

PCB 85264.2

F507

power-AMP 4

T6.3A 250V

5 x 20 mm

IEC 127

28

Page 12
Image 12
Dynacord DPA 4410 dimensions Incorporation Into 19 Flightcases or 19 Rack Systems, Fuses