MAINS OPERATION & RESULTING TEMPERATURES

MAINS OPERATION & RESULTING POWER AMP TEMPERATURES

The following tables are useful in determining power supply and cabling requirements.

The power drawn from the mains network is converted into acoustic output to feed the connected loudspeaker systems plus heat. The difference between drawn power and dispensed power is referred to as leakage power or dissipation (Pd). The amount of heat resulting from power dissipation might remain inside of a rack-shelf and needs to be diverted using appropriate measures. The following table is meant as auxiliary means for calculating temperatures inside of rack-shelf systems/cabinets and the ventilation efforts necessary.

The column “Pd” lists the leakage power in relation to different operational states. The column “BTU/ hr” shows the dispensed heat amount per hour.

 

 

 

 

 

 

 

 

 

Xa 4000

Umains

Imains

Pmains

Pout

Pd (5)

BTU/hr(1)

 

[V]

[A]

[W]

SUB+TOP

[W]

 

 

 

[W]

 

 

idle

230V

 

1

80

-

80

273

 

Max. Output Power @ 8(1)

230V

10,6

1640

600+500

540

1840

 

Max. Output Power @ 4(1)

230V

18,2

3000

1100+900

1000

3410

 

1/3 Max. Output Power @ 4(1)

230V

10,3

1580

366+300

914

3120

 

1/8 Max. Output Power @ 4(1)

230V

4,5

610

137+113

360

1230

 

1/8 Max. Output Power @ 4(2)

230V

5,5

790

137+113

540

1840

1/8 Max. Output Power @ 4(2), (4)

254V

5,5

840

166+137

537

1830

 

Normal Mode (-10dB) @ 4(1)

230V

4,1

550

110+90

350

1190

Rated Output Power (0dB) @ 4(1)

230V

17,2

2800

1000+800

1000

3410

Alert (Alarm) Mode (-3dB) @ 4(1)

230V

12,3

1920

500+400

1020

3480

 

1/3 Max. Output Power @ 2(2)

230V

16,7

2720

600+533

1587

5420

 

1/8 Max. Output Power @ 2(1)

230V

7,2

1050

225+200

625

2130

 

1/8 Max. Output Power @ 2(2)

230V

8,8

1260

225+200

835

2850

(1)

Sine Signal Modulation (80Hz/1kHz)

(2)

Band-limited Pink Noise

 

 

(3)

1BTU = 1055.06J = 1055.06Ws

 

(4)

10% Mains Over Voltage

 

 

(5)

Pd = Leakage Power

 

 

 

 

 

 

 

The following factors allow direct proportional calculation of the power consumption for different mains supply voltages:

100V = 2.3; 120V = 1.9; 220V = 1.05; 240V = 0.96

9

Page 9