To p S i d e C o n t r o l I n s t r u c t i o n s
Preset Filter Cycles
Your spa will automatically filter itself twice each day. The first filter cycle will begin 1 minute after the spa is energized. The second filter cycle will begin 12 hours after the start of the first filter cycle. Filter duration is programmable at the topside panel for 0, 1, 2, 3, 4 or 12 hours. The
default filter time is 2 hours. To program, press the | or | pad, | |||
then the | pad. Continue to press the | or | pad to select | ||
the filter duration. Press the | pad again to exit programming. The |
low speed of pump 1 constantly runs during the filter times (unless the high speed is on). The ozone generator (if installed) will run 24 hours a day.
Freeze Protection
If the high limit sensor detects 40F at the heater, then the high speed of pump 1 and pump 2 (if installed) automatically activates to provide freeze protection. The equipment stays on until the sensor detects
45F at the heater. Freeze protection is activated regardless of the spa's status. In colder climates, an optional additional freeze sensor may be added to protect against freeze conditions. See your dealer for details.
Diagnostic Messages
Overheat Protection (Spa is deactivated)
O H DO NOT ENTER THE WATER. If the spa water has reached 112 F, remove the spa cover to cool the water. Overheating may occur if the filter cycle is set too long. At 110F, the spa should reset itself. If the high limit sensor detects 118F at the heater, the spa will shut down. When the heater cools to 110F, press any button to reset the spa. If the spa will not reset, then shut off power to the spa and call your dealer or service organization.
F L Flow Switch Detection
Flashing alternately with temperature. The filter may need cleaning. The water level is too low. Be sure flow valves are open. FL (NOT FLASHING) a pressure switch has malfunctioned. Contact your dealer or service organization.
S n Sensor (Spa is deactivated)
The
WARNING! SHOCK HAZARD! No User Serviceable Parts.
Do not attempt service of this control. Contact you dealer or service organization for assistance. Follow all owner's manual power connection instructions. Installation must be performed by a licensed electrician and all grounding connections must be properly installed.