The Quick Reference Card provides a quick overview of your spa's main
functions and the operations accessible with your digital control pad.
MC-MP-DY2 SPA PACK
Starting Pump 1:
Press Pump 1 to turn Pump 1 on at low speed. Pressing a second time turns Pump 1 to high speed. A third time turns Pump 1 off. When at high speed, a
The "Pump 1" icon lights up when Pump 1 is on at high speed. It flashes when Pump 1 is on at low speed.
Starting Pump 2:
When blower or Pump 3 are not installed: Press Pump 2 once to turn Pump 2 on at low speed. Pressing a second time turns Pump 2 to high speed. A third time turns pump off. A
The "Pump 2" icon lights up when Pump 2 is on at high speed. It flashes when Pump 2 is on at low speed.
When blower and Pump 3 are installed:
Press Pump 2 once to turn Pump 2 on at low speed. Pressing a second time turns Pump 3 on and Pump 2 to high speed. A third time turns both pumps off. A
Automatic water heater start:
When water temperature is 1˚F (0.5˚C) lower than the Set Point, the heater will automatically turn on until water tempera- ture reaches Set Point plus 1˚F (0.5˚C).
The "Heater" icon lights up when the heater is on. It flashes when there is a request for more heat but the heater has not yet started.
Setting water temperature:
Use Up or Down arrow key to regulate water temperature. The temperature setting will be displayed for 5 seconds to confirm your new selection.
The "Set Point" symbol indicates the
desired temperature, NOT the current water temperature!
Water temperature can be adjusted by 1˚ in- crements from 59 to 104˚F (15 to 40˚C).
Time & temperature display:
The display toggles every 5 seconds alternately showing the hourly time and the current water temperature.
Turning the light on:
Pressing Light key once turns light on at high intensity. Pressing a second time turns light to low intensity. A third time turns light off. A
The "Light" icon is displayed when light is on at high intensity. It flashes when light is on at low intensity.
Fiber Box Option: If spa has an optional fiber box only, pressing Light key turns fiber box (motor & light) on. Pressing again turns fiber box motor off but leaves light on. A third time turns both motor and light off. A
Fiber Box & 12V light (via jumper):
Pressing Light key once turns fiber box (motor
&light) and 12V light output on. Pressing again turns fiber box motor off but leaves lights on. A third time turns 12V light off and a fourth time shut fiber box light. The "Light" icon is displayed when fiber box motor is off and both lights on (or only the fiber box light). It flashes when fiber box (motor & light) and 12V light are on.
unless manually deactivated first. The "Pump 2" icon lights up when Pump 2 and Pump 3 are on at high speed. It flashes when Pump 2 is on at low speed.
Starting Pump 3:
The filter cycle is suspended if the water temperature raises more than 2˚F (1˚C) above Set Point . The "Filter" icon will blink (on 0.5 second, off 0.5 second, on 0.5 second, off 1.5 seconds).
Troubleshooting
Press Pump 3 to turn Pump 3 on. Pressing a second time turns Pump 3 off. A
Starting the blower:
Press Blower to turn blower on at high speed. Press a second time to turn blower to low speed. A third time turns blower off. A
The "Blower" icon lights up when blower is on at high speed. It flashes when blower is on at low speed.
Temperature display unit:
Press and hold Light key for 5 seconds to display water temperature in either Fahr- enheit (˚F) or Celsius (˚C).
Pumps have started up for one minute on several occasions and "Filter Cycle" icon is flashing.
Not a bug but a feature!
Our Smart Winter Mode protects your system from the cold by automatically turning the pumps on for one minute several times a day to prevent water from freezing in pipes.
The display is flashing.
A power failure has occurred. Press any key to reset the system, then reprogram all desired parameters.
Water temperature is displayed.
Water temperature in the spa has reached 112˚F (44˚C).
Do not enter the water! Allow water to cool down. The system will reset au- tomatically when water reaches 109˚F (43˚C).
Call your dealer or service supplier if problem persists.
3 flashing dots are dis- played.
A problem has been de- tected.
Do not enter the water! Check and open water valves. Clean filters if nec- essary. Check water level. Add water if needed.
Shut power off and power your spa up again to reset the system.
Call your dealer or service supplier if problem persists.