VTrak J610s, J310s Product Manual

D01 SAS Addr: 50 00 15 E0 11 4E 5E B2

D02 SAS Addr: 50 00 15 E0 11 4E 80 C2

D03 SAS Addr: 50 00 15 E0 11 4C 22 02

D04 SAS Addr: 50 00 15 E0 11 4D E2 22

D05 SAS Addr: 50 00 15 E0 11 4D 8F B2

D06 SAS Addr: 50 00 15 E0 11 4D D0 62

D07 SAS Addr: 50 00 15 E0 11 4D DE E2

D08 SAS Addr: 50 00 15 E0 11 4D 8E F2

D09 SAS Addr: 50 00 15 E0 11 4C 97 62

D10 SAS Addr: 50 00 15 E0 11 4C 36 62

D11 SAS Addr: No Device Attached

D12 SAS Addr: No Device Attached

CN1 SAS Addr: 50 06 05 B0 00 01 69 64

CN2 SAS Addr: No Device Attached

CN3 SAS Addr: 50 00 15 5D 21 AA 12 3F

Settings

The Enclosure command enables you to make settings for the enclosure. The J310s is shown. The J610s is similar.

Enclosure Critical Temperature – 51°C (123°F) to 61°C (141°F), measured at the backplane

Enclosure Warning Temperature – 10°C (50°F) to 51°C (123°F), measured at the backplane

Controller Critical Temperature – 61°C (141°F) to 71°C (160°F), measured inside the I/O module

Controller Warning Temperature – 10°C (50°F) to 61°C (141°F), measured inside the I/O module

Thermal Management – Monitors enclosure temperature, adjusts fan speeds, displays red LED on cooling unit when a fan fails

Automatic Shutdown – Shuts down the J310s when it reaches the enclosure or controller critical temperature

Minimum Fan Speed – Specifies the minimum fan speed when the J310s reaches enclosure or controller warning temperature

To set the enclosure critical temperature to 61°C (141°F), at the cli> prompt, type enclosure -a mod -s “enc_critical=61” and press Enter.

To enable Thermal Management, at the cli> prompt, type enclosure -a mod -s “thermalmanager=1” and press Enter.

For this command, a 1 enables and a 0 disables.

To enable Automatic Shutdown, at the cli> prompt, type enclosure -a mod -s “allowshutdown=1” and press Enter.