![](/images/new-backgrounds/1194028/19402879x1.webp)
VTrak J610s, J310s Product Manual
D01 SAS Addr: 50 00 15 E0 11 4E 5E B2
D02 SAS Addr: 50 00 15 E0 11 4E 80 C2
D03 SAS Addr: 50 00 15 E0 11 4C 22 02
D04 SAS Addr: 50 00 15 E0 11 4D E2 22
D05 SAS Addr: 50 00 15 E0 11 4D 8F B2
D06 SAS Addr: 50 00 15 E0 11 4D D0 62
D07 SAS Addr: 50 00 15 E0 11 4D DE E2
D08 SAS Addr: 50 00 15 E0 11 4D 8E F2
D09 SAS Addr: 50 00 15 E0 11 4C 97 62
D10 SAS Addr: 50 00 15 E0 11 4C 36 62
D11 SAS Addr: No Device Attached
D12 SAS Addr: No Device Attached
CN1 SAS Addr: 50 06 05 B0 00 01 69 64
CN2 SAS Addr: No Device Attached
CN3 SAS Addr: 50 00 15 5D 21 AA 12 3F
Settings
The Enclosure command enables you to make settings for the enclosure. The J310s is shown. The J610s is similar.
•Enclosure Critical Temperature – 51°C (123°F) to 61°C (141°F), measured at the backplane
•Enclosure Warning Temperature – 10°C (50°F) to 51°C (123°F), measured at the backplane
•Controller Critical Temperature – 61°C (141°F) to 71°C (160°F), measured inside the I/O module
•Controller Warning Temperature – 10°C (50°F) to 61°C (141°F), measured inside the I/O module
•Thermal Management – Monitors enclosure temperature, adjusts fan speeds, displays red LED on cooling unit when a fan fails
•Automatic Shutdown – Shuts down the J310s when it reaches the enclosure or controller critical temperature
•Minimum Fan Speed – Specifies the minimum fan speed when the J310s reaches enclosure or controller warning temperature
To set the enclosure critical temperature to 61°C (141°F), at the cli> prompt, type enclosure
To enable Thermal Management, at the cli> prompt, type enclosure
For this command, a 1 enables and a 0 disables.
To enable Automatic Shutdown, at the cli> prompt, type enclosure
36