![](/images/new-backgrounds/1194028/19402885x1.webp)
| Chapter 3: Management |
|
|
P15 |
P16
P17
P18
P19
InDW:Invalid Dword Count DsEr:Disparity Err Count
DwLo:Dword Sync Loss Count
PhRe:Phy Reset Problem Count CoVi:Code Violations Cnt
PRBS:PRBS Error Count
PhCh:Phy Change Count
The following items are reported in the table above. All counts are hexadecimal:
•Link number – Links are Phys, numbered P0 through P23
•Invalid
•Disparity Error Count
•Phy Reset Problem Count
•Code Violation Count
•
•Phy Change Count
If the count is zero, the counter shows dashes
occur does not necessarily indicate a problem or that the J610s or J310s unit is malfunctioning.
An individual error count incrementing at intervals of less than six minutes indicates a possible problem and requires further investigation.
To clear the link error count, at the cli> prompt, type link
Route Command
Use this command to show the SAS addresses of the devices in your domain.
At the cli> prompt, type route and press Enter.
Routing Table Mapping: |
|
Entry# SAS Address | PortID CnID NextEntry NextValid |
0083 | 500000E01122C533 | 0x10 | CN1 | 0 | |
0121 | 500000E01122C4A3 | 0x10 | CN1 | 0 | |
0226 | 500000E01122C513 | 0x10 | CN1 | 0 | |
0244 | 500000E011246263 | 0x10 | CN1 | 0 | |
0358 | 500000E011231F43 | 0x10 | CN1 | 0 | |
0466 | 500000E0112770B3 | 0x10 | CN1 | 0 |