PROGRAMMING FILTER CYCLE DURATION

PROGRAMMING FILTER CYCLE DURATION

The system automatically performs two filter cycles per day, at 12-hour intervals. During a filter cycle:

Pump 2 runs for one minute, then

Pump 1 runs at low speed for the programmed number of hours

The "Filter Cycle" indicator lights up when the filter cycle is on.

To set filter cycle duration:

Press and hold Filter key until the display shows "xx", representing the currently set filter cycle duration in hours.

Use Up or Down arrow keys to change setting.

0 = no filtration

12 = continuous filtration

When the desired setting is dis- played, press Light key to confirm. A filter cycle starts immediately.

Note: Light needs to be turned off before the filter cycle can be programmed.

The filter cycle is suspended if the water temperature raises more than 2˚F (1˚C) above Set Point or if spa is in use (pumps and light started manually). The "Filter" icon will blink (on 0.5 second, off 0.5 second, on 0.5 second, off 1.5 seconds).

N.B.: After a power failure, the filter cycle duration will return to its default value (2 hours). In this case, the first filter cycle will start one minute after power has been restored.

TROUBLESHOOTING

Pumps have started up for one minute on several occasions and "Filter Cycle" indicator is flashing.

3 flashing dots are displayed.

Water temperature is flashing.

Not a bug but a feature!

Our Smart Winter Mode protects your spa from the cold by automatically turning pumps on for one minute several times a day to prevent water from freezing in pipes.

A problem has been detected.

Do not enter the water! Check and open water valves. Clean filter if necessary. Check water level. Add water if needed.

Shut power off and power your spa up again to reset the system.

Call your dealer or service supplier if problem persists.

Water temperature in the spa has reached 112˚F (44˚C).

Do not enter the water! Allow water to cool down. The system will reset automatically when water temperature reaches 109˚F (43˚C).

Call your dealer or service supplier if problem persists.

The display is flashing.

A power failure has occurred.

 

Press any key to reset the system, then reprogram all

 

desired parameters.