Dynasty Spas SSPA-1 manual Troubleshooting, How To Program The Filter Cycle Duration, Gecko

Models: SSPA-1

1 2
Download 2 pages 26.24 Kb
Page 2
Image 2
HOW TO PROGRAM THE FILTER CYCLE DURATION

HOW TO PROGRAM THE FILTER CYCLE DURATION

The system will automatically perform two filtration cycles per day, 12 hours apart. During a filter cycle, the pump runs at low speed for a predetermined number of hours. The ozonator is also activated. The "Filter" indicator light will be on when a filter cycle is in progress.

To set the filter cycle duration:

Press and hold the Light key for

Use the Up or Down arrow key

When the desired setting is

5 seconds. The display will show

to change the setting.

displayed, press the Light key

the currently set filter cycle duration

0 = no filtration

to confirm. A filter cycle will start

in hours.

12 = continuous filtration

immediately.

An irregularly flashing "Filter" indicator light indicates that the system has stopped filtering after 3 hours because the water temperature exceeds the set point by more than 2˚F (1˚C). If the temperature cools down to 1˚F (0.5˚C) above set point before the scheduled end of the cycle, filtering will resume for the remaining of the programmed duration.

Note: After a power failure, the filter cycle duration

will return to its default value (6 hours). In this case, the first filter cycle will start 12 hours after power has been restored.

TROUBLESHOOTING

Pumps have started up for one minute on several occasions and "Filter Cycle" indicator is flashing.

Not a bug but a feature!

Our Smart Winter Mode protects your spa from the cold by automatically turning pumps on for one minute several times a day to prevent water from freezing in pipes.

3 flashing dots are displayed.

A problem has been detected.

 

Do not enter the water! Check and open water valves.

 

Clean filter if necessary. Check water level. Add water

 

if necessary.

 

Shut power off and power your spa up again to reset the

 

system.

 

Call your dealer or service supplier if problem persists.

 

 

Water temperature is flashing.

Water temperature in the spa has reached 112˚F (44˚C).

 

Do not enter the water! Allow water to cool down. The

 

system will reset automatically when water temperature

 

reaches 109˚F (43˚C).

 

Call your dealer or service supplier if problem persists.

 

 

The display is flashing.

A power failure has occurred. Press any key to reset the

 

system, then reprogram all desired parameters.

9919-100099-B

GECKO

PE D

W I T H

G E C K O ' S

E X C L U SI

 

 

 

VE•

TROUBLESHOOTING3 flashing dots are displayed.The display is flashing.GECKOManual backgroundManual backgroundSmart

Winter

Manual backgroundManual backgroundManual backgroundManual backgroundManual background Mode

1.800.78.GECKO

Page 2
Image 2
Dynasty Spas SSPA-1 manual Troubleshooting, How To Program The Filter Cycle Duration, Gecko, flashing dots are displayed