| BARS DIAGNOSIS SOLUTION |
|
10 | Green | High Battery Voltage | Check Batteries |
9 | Green | Solenoid Brake Fault | Check Motor/Brake Wiring |
8 | Green | Possible Controller Fault | See Authorized Service Center |
7 | Yellow | Possible Joystick Fault | See Authorized Service Center |
6 | Yellow | Inhibit Active | Unplug Charger/Check |
Connections |
|
|
|
5 | Yellow | Right Motor Wiring Fault Check | Right Motor Wiring |
4 | Yellow | Right Motor Disconnected | Check Right Motor Wiring |
3 | Red | Left Motor Wiring Fault | Check Left Motor Wiring |
2 | Red | Left Motor Disconnected | Check Left Motor Wiring |
1 | Red | Low Battery Voltage | Check Batteries/Battery Wiring |
Freewheeling
For convenience, your LIBERTY™ 624 MINI is equipped with two freewheel levers. These levers allow you to disengage the drive motors and maneuver the chair manually. Locate the 2 metal bars protruding from the frame cover and turn them toward the outside of the powerchair. To reengage the drive motors, turn the metal levers back to the forward position. If the lever is difficult to move in either direction, press the lever downward and roll the LIBERTY™ 624 MINI forward and backward slightly. The lever should then move to the desired position.
Eagle Note: It is important to remember that when the LIBERTY™ 624 MINI is in the freewheel position, the braking system is disengaged.
WARNING: Avoid placing the LIBERTY™ 624 MINI in freewheel on an incline as the unit could roll on its own causing injury.
Main Circuit Breaker
The circuit breaker is located under the main body cover on the left rear side of the frame.
The main circuit breaker is a safety feature built into your LIBERTY™ 624 MINI. When the batteries and the motors are subjected to excessive loads, the main circuit breaker might trip to prevent damage to the motors and/or electronics. If this happens, allow the unit to rest for approximately one minute, to allow time for the automatic rest circuit breaker to reset. You may wish to charge the batteries more frequently and have an authorized service center or service station load test the batteries to determine how they operate under normal operation.
Eagle Note: If the main circuit breaker continues to trip, you should return to your authorized LIBERTY™ 624 MINI dealer for service.