Echo PB-755S T, PB-755S H manual Assembly, install blower pipes / stick handle, PB-755SH

Models: PB-755S H PB-755S T

1 32
Download 32 pages 25.51 Kb
Page 12
Image 12
Assembly

12 install blower pipes / stick handle

Assembly

PB-755SH

Manual background WARNINg

Never perform maintenance or assembly procedures with engine running or serious personal injury may result.

install blower pipes / stick handle

(h)

1.Assemble clamps (A) onto both ends of flexible pipe (B).

2.Assemble swivel pipe (C) into flexible pipe (B) and tighten clamp

(A).

3.Assemble flexible pipe (B) to elbow (D) on blower and tighten clamp (A).

NOTE

A light lubricant may be used to ease assembly of flexible pipe to blower elbow.

4.Loosen wing nut (E) completely and open stick handle clamp.

5.Align notches (F) in handle clamp with tabs (G).

6.Slide stick handle onto swivel pipe (C). Stick handle should be angled away from operator.

7.Position stick handle (H) for comfortable operation, and tighten wing nut (E).

8.Assemble straight pipe (I) onto swivel pipe (C), until you feel light resistance. Do not force connection. Hold swivel pipe and turn straight pipe clockwise, engaging positive locking channels, until connection is firm. Do not force connection.

9.Assemble straight pipe with decal (J) to straight pipe (I) as in step 8.

NOTE

Blower use will eventually loosen pipe connections. Exclusive positive locking system allows pipes to be tightened. If loosening occurs, remove two straight pipes and install according to instruc- tions 8 & 9.