Perlick Z2148EMU Installation Instructions, Tapping And Cleaning Procedures, To Restart System

Models: Z2148EMU

1 2
Download 2 pages 38.2 Kb
Page 2
Image 2
INSTALLATION INSTRUCTIONS

INSTALLATION INSTRUCTIONS

TAPPING AND CLEANING PROCEDURES

EXISTING

BEER LINE

AND SEAL

WASHER

P/N 43739

UNIVERSAL

EMPTY KEG

SENSOR AND SEALING TAPPING AND CLEANING PROCEDURES WASHER

REMOVE CLIP/SPRING AND CHECK BALL FROM COUPLER

1.Disconnect keg coupler from keg.

2.Open faucet to relieve line pressure and close when flow ceases.

3.Disconnect beer line including seal washer from keg coupler.

4.Connect beer line including seal washer to external thread of Universal Empty Keg Sensor and turn Beer Flow Control Handle to OFF position. (See Fig. 1). In this position the Universal Empty Keg Sensor acts as a shut-off valve.

5.Where fitted, remove retaining clip/spring and check ball from keg coupler center probe.

6.Insert seal washer supplied into coupling nut on Universal Empty Keg Sensor and couple to the keg coupler.

7.Connect keg coupler to keg and tap keg.

8.Turn Beer Flow Control Handle to CLEAN. (See Fig. 3).

9.Open beer faucet. When solid beer appears, close the faucet.

10.Turn Beer Flow Control Handle ON. (See Fig. 2). The line is full and ready

for service.

Beer Flow Control

Handle Operating

Positions

Fig. 1

Fig. 2

OFF

ON

45°

Fig. 3

CLEAN

Filling the Lines the First Time

1.Turn Beer Flow Control Handle OFF. (See Fig. 1).

2.Tap fresh keg.

3.Turn Beer Flow Control Handle to CLEAN. (See Fig. 3).

4.Open the beer faucet. When solid beer appears, close the faucet. The line is full.

5.Turn Beer Flow Control Handle ON. (See Fig.2). The line is full and ready for service.

When Tapping Fresh Kegs

1.Remove coupler from empty keg.

2.Turn Beer Flow Control Handle OFF. (See Fig. 1).

2.Tap fresh keg in normal manner.

3.Turn Beer Flow Control Handle to CLEAN. position. (See Fig. 3). Wait for five seconds then turn to ON position. (See Fig. 2).

To Restart System

If beer does not flow, first turn the Flow Control Handle to OFF. (See Fig. 1). Then turn Handle to the CLEAN position. (See Fig. 3). Wait for five seconds then turn the Handle to ON position. (See Fig. 2).

To Clean

1.

Untap Keg in usual manner.

2.

Turn Beer Flow Control Handle OFF.

 

(See Fig. 1).

3.

Attach cleaning adapter. Use Perlick’s

 

single cleaning adapter, No. 43657, if

Warranty

Perlick Products are fully guaranteed against defects in both material and workmanship for a period of one year from date of sale. Defective parts will be replaced on a no-charge basis, F.O.B. our factory, subject to our inspection. We are not responsible for parts damaged by alteration, unauthorized service, accident or abuse. All costs incident to replacement to include freight, labor and/or loss of sales are incidental to this warranty and must be borne by the user.

Cleaning Adapters

 

cleaning from faucet to keg. If two or

 

more lines are cleaned, use Perlick’s

 

dual cleaning adapter, No. 43681.

4.

Turn Beer Flow Control Handle to

 

CLEAN and clean as usual. (See Fig. 3).

5.

After flushing, turn Beer Flow Control

 

Handle OFF and retap keg. (See Fig. 1).

No. 43657

No. 43681

6. To restore service, see above instructions.