10
BLOWER REPLACEMENT INSTALLATION
b l
a
c
k
white
FIGURE 8
red
1. Turn off the electri- |
|
cal power and the gas | FIGURE 11 |
supply to the fireplace |
|
insert. |
|
2. Open the glass door |
|
and remove the logs |
|
and fibre bricks, if in- |
|
stalled. |
|
FIGURE 9
BLOWER ACCESS COVER
3.Remove the blower access cover held on with 4 screws.
FIGURE 10
BLOWER ACCESS COVER REMOVED
MOUNTING
PLATE
4.Remove the blower mounting plate with the blower
attached.
NOTE: Check the blower gasket for damage. Replace if
THERMODISC / BRACKET ASSEMBLY
damaged.
5.Disconnect the two blower wires. Remove the blower from the mounting plate and replace.
For thermodisc replacement: Remove the mounting bracket secured to the underside of the burner base. Re- move the thermodisc from the bracket and replace.
6.Reconnect the two wires.
7.Turn the gas supply and electricity back on.
Because the blower is thermally activated, when turned on, it will automatically start approximately
Drywall dust will penetrate into the blower bearings caus- ing irreparable damage and must be prevented from com- ing into contact with the blower or its compartment. Any damage resulting from this condition is not covered by the warranty policy.
ADJUSTMENTS
PILOT BURNER ADJUSTMENT
shutter will cause a more yellow flame, but can lead to carboning. Opening the air shutter will cause a more blue flame, but can cause flame lifting from the burner ports.
VENTURI ADJUSTMENT
The flame may not appear yellow immediately; allow 15 to 30 minutes for the final flame colour to be established.
OL
HI
TOLIP
N O
O
F
F
TOLIP
PILOT SCREW | FIGURE 14 |
|
FIGURE 13
FIGURE 12
Air shutter adjustment must only be done by a qualified
gas installer!