Napoleon Fireplaces GDI-30P Blower Replacement Installation, Adjustments, Pilot Burner Adjustment

Models: GDI-30P GDI-30N

1 16
Download 16 pages 22.56 Kb
Page 10
Image 10
BLOWER REPLACEMENT INSTALLATION

10

BLOWER REPLACEMENT INSTALLATION

b l

a

c

k

white

FIGURE 8

red

1. Turn off the electri-

 

cal power and the gas

FIGURE 11

supply to the fireplace

 

insert.

 

2. Open the glass door

 

and remove the logs

 

and fibre bricks, if in-

 

stalled.

 

FIGURE 9

BLOWER ACCESS COVER

3.Remove the blower access cover held on with 4 screws.

FIGURE 10

BLOWER ACCESS COVER REMOVED

MOUNTING

PLATE

4.Remove the blower mounting plate with the blower

attached.

NOTE: Check the blower gasket for damage. Replace if

THERMODISC / BRACKET ASSEMBLY

damaged.

5.Disconnect the two blower wires. Remove the blower from the mounting plate and replace.

For thermodisc replacement: Remove the mounting bracket secured to the underside of the burner base. Re- move the thermodisc from the bracket and replace.

6.Reconnect the two wires. Re-install the blower gasket. Reattach the blower mounting plate and blower access cover. Replace the logs. Close the fire viewing door.

7.Turn the gas supply and electricity back on.

Because the blower is thermally activated, when turned on, it will automatically start approximately 5-15 minutes after lighting the fireplace insert and will run for approximately 30-45 minutes after the fireplace insert has been turned off. Use of the fan increases the output of heat.

Drywall dust will penetrate into the blower bearings caus- ing irreparable damage and must be prevented from com- ing into contact with the blower or its compartment. Any damage resulting from this condition is not covered by the warranty policy.

ADJUSTMENTS

PILOT BURNER ADJUSTMENT

shutter will cause a more yellow flame, but can lead to carboning. Opening the air shutter will cause a more blue flame, but can cause flame lifting from the burner ports.

VENTURI ADJUSTMENT

The flame may not appear yellow immediately; allow 15 to 30 minutes for the final flame colour to be established.

OL

HIb l

TOLIP

N O

O

F

F

TOLIP

PILOT SCREW

FIGURE 14

 

FIGURE 13

FIGURE 12

Air shutter adjustment must only be done by a qualified

gas installer!

W415-0384 / D / 09.13.05

Page 10
Image 10
Napoleon Fireplaces GDI-30P Blower Replacement Installation, Adjustments, Pilot Burner Adjustment, Venturi Adjustment