4

GENERAL INSTRUCTIONS

 

GENERAL INFORMATION

 

 

 

THIS GAS FIREPLACE INSERT SHOULD BE INSTALLED AND SERVICED BY A QUALIFIED INSTALLER to con- form with local codes. Installation practices vary from re- gion to region and it is important to know the specifics that apply to your area,

for example: in Massachusetts State:

The fireplace damper must be removed or welded in the open position prior to installation of a fireplace insert or gas log.

The appliance off valve must be a “T” handle gas cock.

The flexible connector must not be longer than 36 inches.

The appliance is not approved for installation in a bedroom or bathroom unless the unit is a direct vent sealed combustion product.

A carbon monoxide detector is required in all rooms containing gas fired appliances.

WARNING: This product must be installed by a licensed plumber or gas fitter when installed within the commonwealth of Massachusetts.

In absence of local codes, install to the current CAN1- B149 Installation Code in Canada or to the National Fuel Gas Code, ANSI Z223.1, and NFPA 54 in the United States. Mobile home installation must conform with local codes or in the absence of local codes, install to the current standard for gas equipped mobile housing CAN/ CSA Z240 MH Series in Canada or ANSI Z223.1 and NFPA 54 in the United States.

Purge all gas lines with the glass door of the fireplace insert opened. Assure that a continuous gas flow is at the burner before closing the door.

Under extreme vent configurations, allow several min- utes (5-15) for the flame to stabilize after ignition.

Objects placed in front of the fireplace must be kept a minimum of 48" away from the front face of the unit.

The fireplace insert and its individual shutoff valve must be disconnected from the gas supply piping system during any pressure testing of that system at test pressures in excess of 1/2 psig (3.5 kPa). The fireplace insert must be isolated from the gas supply piping system by closing its individual manual shutoff valve during any pressure test- ing of the gas supply piping system at test pressures equal to or less than 1/2 psig (3.5 kPa).

A 1/8 inch NPT plug, accessible for test gauge connection, must be installed immediately upstream of the gas supply connection to the fireplace insert.

The fireplace insert must be electrically connected and grounded in accordance with local codes. In the absence of local codes, use the current CSA C22.1 CANADIAN ELEC- TRICAL CODE in Canada or the ANSI/NFPA 70 NATIONAL ELECTRICAL CODE in the United States. The blower power cord must be connected into a properly grounded recepta-

cle. The grounding prong must not be removed from the cord plug.

FOR YOUR SATISFACTION, THIS FIREPLACE INSERT HAS BEEN TEST-FIRED TO ASSURE ITS OPERATION AND QUALITY!

Minimum inlet gas supply pressure is 4.5 inches water column for natural gas and 11 inches water column for propane. Maximum inlet gas pressure is 7 inches water column for natural gas and 13 inches water column for propane. Manifold pressure under flow conditions is 3.5 inches water column for natural gas and 10 inches water column for propane. When the fireplace is installed at el- evations above 4,500ft, and in the absence of specific rec- ommendations from the local authority having jurisdiction, the certified high altitude input rating shall be reduced at the rate of 4% for each additional 1,000ft.

Expansion / contraction noises during heating up and cool- ing down cycles are normal and to be expected.

Maximum input is 24,500 BTU/hr for natural gas and pro- pane. Maximum output for natural gas and propane is 20,825 BTU/hr at an efficiency of 85% with the fan on. The maximum A.F.U.E. (annual fuel utilization efficiency) rating is 82%. This fireplace insert is not approved for closet or recessed installations. It is approved for bathroom, bed- room and bed-sitting room installations and is suitable for

mobile homes. The natural gas model is suitable for in- stallation in a mobile home that is permanently positioned on its site and fuelled with natural gas.

This insert must be recessed into a vented noncombus- tible wood-burning fireplace (prefabricated or masonry) only. The minimum fireplace opening size in which the heater is to be installed is:

HEIGHT 21.75" WIDTH 28" DEPTH 18"

The minimum allowable chimney flue size is 6" round. The minimum distance, from the bottom of a combustible mantle projecting 3" maximum from the wall to the top of the louvre opening, is 12". A non-combustible hearth must

CARE OF GLASS, AND PLATED PARTS

protrude a minimum of 18" from the unit unless the insert is elevated a minimum of 12" above the combustible flooring. Do not use abrasive cleaners to clean these parts. Buff lightly with a clean dry cloth.

The glass is 3/16" ceramic glass available from your Na- poleon / Wolf Steel Ltd. dealer. DO NOT SUBSTITUTE MA- TERIALS. Clean the glass after the first 10 hours of opera- tion with a recommended gas fireplace glass cleaner. Thereafter clean as required. DO NOT CLEAN GLASS

W415-0384 / D / 09.13.05

Page 4
Image 4
Napoleon Fireplaces GDI-30P, GDI-30N manual General Instructions General Information, Care of GLASS, and Plated Parts

GDI-30P, GDI-30N specifications

Napoleon Fireplaces has long been recognized for its innovative designs and high-quality heating solutions. Among their impressive lineup, the GDI-30P and GDI-30N gas fireplaces stand out as exceptional choices for those seeking both functionality and aesthetic appeal. These models are particularly popular due to their combination of cutting-edge technology, energy efficiency, and customizable features.

One of the key characteristics of the GDI-30P and GDI-30N is their impressive heat output. With an input of up to 30,000 BTUs, these fireplaces can efficiently warm a variety of spaces, making them suitable for homes of various sizes. This high efficiency not only ensures comfort but also reduces energy costs, making them an economical choice for homeowners.

Both units feature a direct venting system, which allows for safe and efficient operation. The direct vent technology ensures that combustion gases are expelled outside the home, while drawing in fresh air for combustion. This system greatly increases safety, as it prevents harmful gases from entering living spaces.

Aesthetically, the GDI-30P and GDI-30N embrace a modern design with clean lines and a large viewing area. The expansive glass front creates an inviting atmosphere, allowing homeowners to enjoy the mesmerizing flames from multiple angles. The units come with various media options, including traditional logs and contemporary glass, allowing for personalization to match any home décor.

Another important aspect of these fireplaces is their advanced control system. Users can easily adjust the flame height and heat output with a remote control or wall switch, providing convenience at their fingertips. The units also incorporate Napoleon’s proprietary electronic ignition system, which ensures reliable start-up and consistent performance.

In terms of building and safety features, both models are designed with a robust construction that ensures longevity. They come equipped with a safety screen, which minimizes the risk of accidental contact with the hot surface. Additionally, their zero-clearance design allows for versatile installation options, including direct installation into existing structures.

Overall, Napoleon Fireplaces GDI-30P and GDI-30N models combine comfort, safety, and contemporary design. With their efficient heating capabilities, customizable aesthetics, and advanced technologies, they offer a fantastic solution for anyone looking to enhance their home with the warmth and ambiance of a gas fireplace.