| OPERATION | ||||
| 
 | 
 | 
 | 
 | |
| Starting Warm Engine | 
 | |||
| A | ||||
| The starting procedure is the same as Cold Start except DO | ||||
| NOT close the choke, and do not depress throttle trigger to wide | 
 | |||
| open position. | 
 | |||
| 
 | 
 | 
 | 
 | |
| 
 | 
 | 
 | 
 | |
| 
 | 
 | 
 | 
 | |
| 
 | 
 | 
 | 
 | |
The attachment should not move at idle, otherwise serious personal injury may result.
Note: If attachment moves, readjust carburetor according to “Carburetor Adjustment” instructions in this manual or see your ECHO Dealer.
1.Stop Switch
Move stop switch (A) away from the STOP position.
2.Purge Bulb
| 
 | Pump purge bulb (C) until fuel is visible and flows freely in the | B | |
| 
 | clear fuel tank return line. Pump bulb an additional 4 or 5 | ||
| 
 | 
 | ||
| 
 | times. | 
 | |
| 
 | 
 | C | |
| 
 | 
 | D | |
| 3. | Recoil Starter | 
 | |
| 
 | |||
| 
 | Lay the unit on a flat area and keep movable attachment parts | 
 | |
| 
 | clear of all obstacles. Firmly grip throttle handle and throttle | 
 | |
| 
 | trigger lockout with left hand. Rapidly pull recoil starter | 
 | |
| 
 | handle/rope (D) until engine fires. | 
 | |
| Note: If engine does not start after 5 pulls, use Cold Start | 
 | ||
| 
 | Procedure. | D | |
| 
 | 
 | ||
| Stopping Engine | 
 | ||
| A | |||
| 1. | Throttle | ||
| 
 | Release throttle and allow engine to return to idle before | 
 | |
| 
 | shutting off engine. | 
 | |
2.Stop Switch
Move stop switch (A) to STOP position.
If engine does not stop when stop switch is moved to STOP position, close choke - COLD START position - to stall
engine. Have your ECHO dealer repair stop switch before using unit again.
| 18 | X7502026303 | 
© 6/2014 ECHO Inc.