Echo SRM - 280U manual starting warm engine, Purge Bulb, Recoil Starter, Stop Switch, A C D

Models: SRM - 280U

1 40
Download 40 pages 17.15 Kb
Page 20
Image 20
starting warm engine

20 2.Purge Bulb

starting warm engine

The starting procedure is the same as Cold Start except DO NOT close the choke, and do not hold throttle trigger fully depressed.

3.Recoil Starter WARNING

The attachment should not move at idle, otherwise serious personal injury may result.

NOTE

If attachment moves, readjust carburetor according to “Carburetor Adjustment” instructions in this manual or see your ECHO Dealer.

1.Stop Switch

Move stop switch button (A) forward away from the STOP posi- tion.

2.Purge Bulb

Pump purge bulb (C) until fuel is visible in the "Clear" fuel return line.

NOTE

Lightly place knee on drive shaft to stabilize unit during starting. Do not apply excessive downward force or damage to unit can oc- cur.

3.Recoil Starter

Lay the unit on a flat area and keep movable attachment parts clear of all obstacles. Rapidly pull the recoil starter handle (D) until the engine fires.

NOTE

If engine does not start after 5 pulls, use Cold Start Procedure.

AA

C

D

Page 20
Image 20
Echo SRM - 280U manual starting warm engine, Purge Bulb, Recoil Starter, Stop Switch, A C D