5 Management Software Guide

Diagnostic Function

Fault Information

Show some information likes Trunk Port Fault, Network Loop Fault Test, and Gigabit PHY existence report for Gigabit Port G1G2.

Device Reset

The software reset will reset the system to the initial state. The MAC table and VLAN table data will be kept. All the current user configured values of internal registers will be kept. The EEPROM download will NOT be done again. But the system will restart the process of Auto Negotiation . The hardware reset will reset all the system at a initial state like the process of power on hardware reset.

30

Ecom ES24F2G Gigabit Ethernet Switch User’s Manual V1.0