(9)Leaving windows or doors slightly open (even a few inches) will significantly reduce the risk of high levels of CO occurring. The high levels of
(10)Install CO Alarms in all the areas recommended in this leaflet.
(11)Recognise that CO poisoning may be the cause when family members suffer from
| 10. TECHNICAL SPECIFICATION |
|
|
Power | : Three Alkaline AA type batteries (supplied) |
CO Sensitivity | : Meets BS EN 50291: 2001. |
| Unit operates as per Table B (on page 8). |
Electromagnetic | : Complies with BS EN 50270 |
Compatibility |
|
Test/Hush Button | : Checks electronics and horn. |
| When the unit is alarming, after sensing CO, pressing the test/hush button |
| will immediately stop the horn (the red light will continue to flash). If CO is |
| still present the red light and the horn will turn on again after about 4 |
| minutes. The unit can only be silenced once during a CO incident. At 300 |
| ppm CO the unit cannot be silenced. (With interconnected units, the hush |
| only works on the alarm sensing CO). |
26