B15583/R0/204EN&205EN/U&C 8/6/06 1:54 PM Page 9
NEVER IGNORE THE ALARM.
NOTE: The CO Alarm may sound if cigarette smoke is blown into it, or aerosols are released nearby.
CO ALARM MEMORY (Ei205EN, Ei205ENA & Ei205CEN only)
-Red light is Off – No CO detected since reset or power up.
-Red light flashes 2 times (in 2 seconds) every 40 seconds, 50 ppm CO detected for at least about 90 minutes.
-Red light flashes 4 times (in 2 seconds) every 40 seconds, 100 ppm CO detected for at least about 40 minutes.
-Red light flashes 8 times (in 2 seconds) every 40 seconds, 300 ppm CO detected for at least about 3 minutes.
When the test button is pressed the horn will sound, and the red light will only flash if the unit has previously detected CO and been in alarm. The flash rate indicates the level of CO as in Table B.
9