LAMP REPLACEMENT

WHEN THE PROJECTION LAMP OF THIS PROJECTOR DRAWS TO AN

END, THE LAMP REPLACEMENT INDICATOR LIGHTS YELLOW AND THE

WARNING MESSAGE “LAMP REPLACEMENT” APPEARS AS THE RIGHT

FIGURE. WHEN THE WARNING MESSAGE IS DISPLAYED, THE

PROJECTION LAMP SHOULD BE REPLACED.

To terminate the warning message.

Replace the Projection Lamp and reset the LAMP REPLACEMENT MONITOR TIMER (See “LAMP AGE” section on page 52.), and the warning message is terminated.

To erase the warning message in a moment.

To erase the warning message for a moment, move the arrow to “YES” by pressing the POINT UP/DOWN BUTTON(s) and then press the SELECT (REAR CLICK) BUTTON. This procedure is temporary measure, and the warning massage appears again when the projector is turned on next time.

For continued safety, replace with a lamp assembly of the same type.

Allow the projector to cool for at least 45 minutes before you open the lamp cover. The inside of the projector can become very hot.

Do not drop the lamp module or touch the glass bulb I The glass

can shatter and cause injury.

Follow these steps to replace the lamp assembly.

1.Turn off the projector and allow the projector to cool thoroughly.

2.Disconnect the AC cord from the projector.

3.Remove 2 screws with a screwdriver and remove the lamp cover.

4.Remove 2 screws with a screwdriver and pull out the lamp assembly by grasping the handle.

5.Replace the lamp assembly.

6.Tighten 4 screws to secure the lamp cover to the lamp assembly.

7.Connect the detachable AC cord to the projector.

8.Reset the lamp replacement monitor timer.

(See “LAMP AGE” section on page 52.)

NOTE: Do not reset the LAMP REPLACEMENT MONITOR TIMER, except after the lamp is replaced.

Page 54
Image 54
Eiki LC-SXIUL instruction manual Lamp Replacement