Electrical Adjustments

No.

 

Adjustment Item

Initial Value

Range

Input source / Description

 

16

 

R_BLK_DC

80/80/80

0 ~ 255

AV Pedestal Adjustment video/1080i,1035i,720p/480p,525p

 

17

 

VRB

115

0 ~ 255

dac3

A/D Ref Voltage Adjustment {BOTTOM]

18

 

GVRT

130

0 ~ 255

dac2

A/D Ref Voltage Adjustment [TOP]

19

 

BVRT

130

0 ~ 255

dac2

 

20

 

RVRT

130

0 ~ 255

dac2

 

21

 

R_V_COM_CEILING

0

0 ~ 255

dac2 R-common center adjustment, deferential value at Ceiling On (0: ±0, 1: +1, 255: -1)

22

 

G_V_COM_CEILING

0

0 ~ 255

dac2 G-common center adjustment, deferential value at Ceiling On (0: ±0, 1: +1, 255: -1)

23

 

B_V_COM_CEILING

0

0 ~ 255

dac2 B-common center adjustment, deferential value at Ceiling On (0: ±0, 1: +1, 255: -1)

24

 

NRSB_CEILING

0

0 ~ 255

NRSB , deferential value at Ceiling On (0: ±0, 1: +1, 255: -1)

 

25

 

NRSA_CEILING

0

0 ~ 255

NRSA , deferential value at Ceiling On (0: ±0, 1: +1, 255: -1)

 

 

 

 

 

 

 

Group: 6 TC90A69F

 

 

 

 

0

 

Y-EQ_GAIN

3

0 ~ 3

 

 

1

 

Y-EQ_N_C_LIM

3

0 ~ 3

 

 

2

 

V-ENH_GAIN

4

0 ~ 7

 

 

3

 

V_ENH_CORING

2

0 ~ 3

 

 

4

 

NTSC443_SW

1

0 ~ 1

Set for input signal system 0:NTSC4.431:PAL60 (It is effective when input signal is NTSC4.43)

 

 

 

 

 

 

 

Group: 10

Option

 

 

 

 

0

 

Lamp Time Monitor

-

0~8738

Read only

 

1

 

RS232C Baudrate

0

0 ~ 1

0: 19200bps1: 9600bps

 

2

 

Shootout Mode

0

0 ~ 1

1: Shoot Out Mode Enable0: Disable

 

3

 

Cooling Time

3

0 ~ 15

Cooling time setting 1:30 sec. 3:90 sec. 15:450 sec. 0:continuously On

4

 

Hi-Land SW

0

0 ~ 255

0: Land mode(Normal operation) 1: High-land mode(Fan spinning in max speed)

5

 

V-Douki SW

0

0 ~ 1

0:V synchronized1:V not synchronized

 

6

 

Lamp Total Time

-

0~65535

Read only

 

7

 

Net Board Reset

1

0 ~ 1

0: Reset unable, 1: Reset enable

 

8

 

Keystone Option

0

0 ~ 1

0:Fixed limitation 1:Change limitation according to input signal

9

 

Syukka SW

0

0 ~ 10

Reset user control value when the data changes to 10 and turns to 0.

10

 

Color Shading SW

1

0 ~ 1

0:On 1:Off

 

11

 

RC Enable/Disable

0

0 ~ 3

0: Activate both Front and Rear RC 1:Prohibition-Front 2:Prohibition-Front 3:Deactivate both Front and Rear RC

12

 

Lamp Dim Level

0

0 ~ 10

0: Maximum (250W)10:Minimum(200W)

 

13

 

Lamp Warning Time

1000

0~65535

in hours, can not be changed

 

14

 

Forced NOBRAND

0

0 ~ 1

0:Normal 1:On

 

15

 

Forced Video Mute Off

0

0 ~ 1

0:VideoMuteOn(Normal) 1:Forced VideoMuteOff

 

16

 

Fan Control SW for Testing

0

0 ~ 4

0: Normal, 1: Normal Min., 2: NormalMax., 3: Eco Min., 4: Eco Max. but not be memorized

Group: 11

Fan Control

 

 

 

 

0

 

FAN_TEMP_A_WARNING

39

30 ~ 100

Temperature A to judge the abnormal (Not memorized) Room

1

 

FAN_TEMP_B_WARNING

50

30 ~ 100

Temperature B to judge the abnormal (Not memorized) Panel

2

 

FAN_TEMP_C_WARNING

67

30 ~ 100

Temperature C to judge the abnormal (Not memorized)lamp

 

3

 

FAN_TEMP_B-A_WARNING

25

0 ~ 100

Temperature B-A to judge the abnormal (Not memorized) Detection of filter croggle

4

 

FAN_TEMP_C-A_WARNING

43

0 ~ 100

Temperature C-A to judge the abnormal (Not memorized) Detection of filter croggle

5

 

FAN_CONTROL_SW

0

0 or 1

0:Fan Control automatically 1:Fan Control Manually

FAN Voltage Adjustment

6

 

FAN_A_SPEED

-

0 ~ 255

Only effective when FAN_CONTROL_SW = 1

 

7

 

FAN_B_SPEED

-

0 ~ 255

Initial Normal/Eco

 

8

 

FAN_C_SPEED

-

0 ~ 255

 

 

9

 

FAN_TEMP_A_MONI

-

-

Read only

 

10

 

FAN_TEMP_B_MONI

-

-

 

 

11

 

FAN_TEMP_C_MONI

-

-

 

 

12

 

FAN_ANZEN_MINMAX

1

0 or 1

Only effective when FAN_CONTROL_SW=1, it can be used with10-12 but not be memorized.

13

 

TEMP_NOWARNING_TIME

3

0 ~ 5

Do not detect temp error within specified time after turn on.

 

14

 

NOR_TEMP_FAN1_MIN

28

 

FAN1 temperature to start the control, Normal

 

15

 

NOR_TEMP_FAN1_MAX

36

 

FAN1 temperature to end the control, Normal

 

16

 

NOR_TEMP_FAN2_MIN

28

0~255

FAN2 temperature to start the control, Normal

 

17

 

NOR_TEMP_FAN2_MAX

36

 

FAN2 temperature to end the control, Normal

 

18

 

NOR_TEMP_FAN3_MIN

28

 

FAN3 temperature to start the control, Normal

 

19

 

NOR_TEMP_FAN3_MAX

36

 

FAN3 temperature to end the control, Normal

 

20

 

NOR_VALU_FAN1_MIN

90

 

FAN1 control minimum value, Normal( 0: Fan voltage 0V, 255:Fan voltage 25.5V)

21

 

NOR_VALU_FAN1_MAX

135

 

FAN1 control maximum value, Normal

 

22

 

NOR_VALU_FAN2_MIN

80

0~255

FAN2 control minimum value, Normal

 

23

 

NOR_VALU_FAN2_MAX

135

 

FAN2 control maximum value, Normal

 

24

 

NOR_VALU_FAN3_MIN

70

 

FAN3 control minimum value, Normal

 

25

 

NOR_VALU_FAN3_MAX

105

 

FAN3 control maximum value, Normal

 

26

 

ECO_TEMP_FAN1_MIN

28

 

FAN1 temperature to start the control, Eco

 

27

 

ECO_TEMP_FAN1_MAX

36

 

FAN1 temperature to end the control, Eco

 

28

 

ECOTEMP_FAN2_MIN

28

0~255

FAN2 temperature to start the control, Eco

 

29

 

ECO_TEMP_FAN2_MAX

36

 

FAN2 temperature to end the control, Eco

 

30

 

ECO_TEMP_FAN3_MIN

28

 

FAN3 temperature to start the control, Eco

 

31

 

ECO_TEMP_FAN3_MAX

36

 

FAN3 temperature to end the control, Eco

 

32

 

ECO_VALU_FAN1_MIN

55

 

FAN1 control minimum value, Eco

 

33

 

ECO_VALU_FAN1_MAX

120

 

FAN1 control maximum value, Eco

 

34

 

ECO_VALU_FAN2_MIN

70

0~255

FAN2 control minimum value, Eco

 

35

 

ECO_VALU_FAN2_MAX

100

 

FAN2 control maximum value, Eco

 

36

 

ECO_VALU_FAN3_MIN

55

 

FAN3 control minimum value, Eco

 

37

 

ECO_VALU_FAN3_MAX

75

 

FAN3 control maximum value, Eco

 

38

 

HINOR_TEMP_FAN1_MIN

22

 

FAN1 temperature to start the control, HighLand Normal

 

39

 

HINOR_TEMP_FAN1_MAX

32

 

FAN1 temperature to end the control, HighLand Normal22

 

40

 

HINOR_TEMP_FAN2_MIN

22

0~255

FAN2 temperature to start the control, HighLand Normal

 

41

 

HINOR_TEMP_FAN2_MAX

32

 

FAN2 temperature to end the control, HighLand Normal

 

42

 

HINOR_TEMP_FAN3_MIN

22

 

FAN3 temperature to start the control, HighLand Normal

 

43

 

HINOR_TEMP_FAN3_MAX

32

 

FAN3 temperature to end the control, HighLand Normal

 

44

 

HINOR_VALU_FAN1_MIN

90

 

FAN1 control minimum value, HighLand Normal (0: Fan voltage 0V, 255:Fan voltage 25.5V)

45

 

HINOR_VALU_FAN1_MAX

138

 

FAN1 control maximum value, HighLand Normal

 

 

 

 

 

 

 

 

-33-

Page 35
Image 35
Eiki LC-XG210 service manual Group 6 TC90A69F

LC-XG210 specifications

The Eiki LC-XG210 is a high-performance LCD projector designed for professional presentations and educational use. This projector stands out due to its impressive brightness, exceptional image quality, and versatile connectivity options, making it an ideal choice for a variety of settings, including classrooms, conference rooms, and auditoriums.

One of the primary features of the Eiki LC-XG210 is its remarkable brightness, with a lumen output of 3,200 ANSI lumens. This high brightness level ensures that presentations remain vibrant and clear, even in well-lit environments. Coupled with a native resolution of XGA (1024 x 768 pixels), the projector delivers sharp text and detailed images, making it suitable for displaying both graphics and video footage.

The LC-XG210 utilizes advanced 3LCD technology, which ensures accurate color reproduction and enhanced color brightness. This technology provides a wide color gamut, allowing users to enjoy rich and lifelike colors without any noticeable color distortion. The projector also features a high contrast ratio, contributing to deeper blacks and more vivid images, further enhancing the overall viewing experience.

Connectivity is a crucial aspect of the Eiki LC-XG210, and it excels in this area with a range of input options. It includes multiple VGA inputs, composite and S-Video inputs, as well as a USB port for easy connection to computers and other devices. This flexibility allows users to seamlessly switch between different sources without the need for additional adapters.

Additionally, the projector is equipped with a powerful built-in speaker that delivers clear audio, eliminating the need for external sound systems in smaller venues. Its lightweight and portable design make it easy to transport, enabling users to set it up quickly in various locations.

The Eiki LC-XG210 also boasts a user-friendly interface and advanced features such as automatic keystone correction, which simplifies the setup process by automatically adjusting the image to fit the screen perfectly. This projector is designed for reliability and longevity, evident in its long lamp life of up to 5,000 hours in eco mode, reducing maintenance costs and enhancing overall value.

In summary, the Eiki LC-XG210 is a versatile and powerful projector that combines high brightness levels, advanced LCD technology, and extensive connectivity options. These features make it an excellent choice for any professional or educational environment, ensuring outstanding image quality and reliability for diverse presentation needs.